A specific OpenTP1 can also be run in the multiOpenTP1 configuration by using the environment variables shown below. The environment variables must be defined for each login environment in the user startup files (.profile, .login).
- DCDIR
- Specifies the full path name of the OpenTP1 directory. Use a maximum of 50 bytes for the directory name to be set in DCDIR. You cannot use symbolic links for OpenTP1 directories.
- DCCONFPATH
- Use a maximum of 246 bytes to specify the full path name of the directory for storing OpenTP1 definitions.
- DCUAPCONFPATH
- If you want to store the OpenTP1 user service definition files in a directory other than the directory specified in the DCCONFPATH environment variable, use a maximum of 246 bytes to specify the full path name of the directory.