KFCT73438-E
cannot change prf trace level. ID= aa....aa reason code = bb....bb - cc....cc.
- aa....aa
-
PRF identifier
If the PRF identifier cannot be identified, **** is displayed.
- bb....bb
-
Reason code
- cc....cc
-
Internal system code
Description
The PRF trace level cannot be changed.
The cprflevel command terminates with an error.
Action
Based on the list of reason codes described in the following table, investigate the cause, and then remove the cause of the error. After the cause of the error is removed, re-execute the cpflevel command. However, when exclusive control fails, an internal error occurs, and a message other than the listed reason codes appears, contact our customer service.
Reason code |
Cause |
---|---|
106 |
The environment variable PRFSPOOL may not have been specified or the directory specified in the environment variable PRFSPOOL may not have been created correctly. |
117 |
The specified option is invalid. |
3202 |
The PRF daemon with the specified PRF identifier is not running. |
3203 |
An attempted exclusive control has failed. |
8001 |