Hitachi

Hitachi Application Server V10 Messages


KFCT73430-E

prf tracing service cannot be started. ID= aa....aa reason code = bb....bb - cc....cc.

aa....aa

PRF identifier

If the PRF identifier cannot be identified, **** is displayed.

bb....bb

Reason code

cc....cc

Internal system code

Description

An attempt to start the PRF daemon service has failed.

The PRF daemon service terminates.

Action

Based on the list of reason codes described in the following table, investigate the cause, and then remove the cause of the error. However, when exclusive control fails, an internal error occurs, and a message other than the listed reason codes appears, please contact our customer service.

Reason code

Cause

101

Memory is insufficient.

102

Memory is insufficient.

104

The new message queue ID in the msgget system call was not allocated. Check the usage status with the ipcs command. If an unnecessary message queue exists, the queue needs to be deleted with the ipcrm command.

106

The environment variable PRFSPOOL may not have been specified or the directory specified in the environment variable PRFSPOOL may not have been created correctly.

112

The specified trace service is already running, or the trace service is not running but a new trace service cannot be started because the running process is collecting the trace.

115

An attempt to access the shared memory used in the PRF daemon service has failed.

117

The specified option is invalid.

118

The shared memory used in the PRF daemon service cannot be reused. Add the -PrfRemakeBuffer option to the cprfstart command, and then execute the command.

119

An attempt to re-create the shared memory used in the PRF daemon service has failed. If the process using the PRF daemon service is running, the shared memory cannot be re-created. If you want to recreate the shared memory and start the PRF daemon, terminate the process that is using the PRF daemon service. Note that, the shared memory is re-created in the following cases:

  • When the cprfstart command is executed with the -PrfRemakeBuffer option added

  • When the cprfstart command is executed with a value different from the previous value (if value was not specified previously, specify a value other than 8194) specified in the -PrfTraceBufferSize option

502

An error occurred while creating the necessary environment to control the PRF daemon service.

1601

An error occurred in the system call.

3201

A timeout occurred when starting the PRF daemon. The PRF daemon may be running normally.

3203

An attempted exclusive control has failed.

8001

An internal error occurred.