KFCT73002-E
prf tracing service cannot be started. ID:aa....aa reason code=bb....bb-cc....cc
Description
An error occurred when starting the PRF daemon service.
The PRF daemon terminates.
Action
Based on the list of reason codes described in the following table, investigate the causes, remove the cause of the error, and then restart the PRF daemon.
Reason code |
Cause |
---|---|
101 |
Memory is insufficient. |
102 |
Memory is insufficient. |
103 |
An I/O error occurred when verifying the file or when creating a new file. |
104 |
The new message queue ID in the msgget system call was not allocated. Check the usage status with the ipcs command. If an unnecessary message queue exists, the queue needs to be deleted with the ipcrm command. |
106 |
The directory specified in the environment variable PRFSPOOL may not have been created correctly. |
112 |
The specified trace service is already running or the trace service is not running, but a new trace service cannot be started as the running process is collecting the trace. |
114 |
The shared memory used in the PRF daemon service is destroyed. |
115 |
The address of the shared memory used in the PRF daemon service cannot be acquired. |
401 |
An error occurred while opening an internal control file of the PRF daemon service. |
402 |
An internal control file of the PRF daemon service is destroyed. |
403 |
An error occurred in the internal control file of the PRF daemon service. The directory specified in the environment variable PRFSPOOL may not have been created correctly. |
404 |
The specified trace file creation directory is invalid. |
502 |
An error occurred while creating the necessary environment to control the PRF daemon service. |
1601 |
An error occurred in the system call. |