Hitachi

Hitachi Application Server V10 Messages


KDKD10158-E

A mismatch occurred between the configuration information in memory and the configuration information in domain.xml, because domain.xml could not be updated. (details = aa....aa)

aa....aa

Details

Description

An error occurred while updating domain.xml. The configuration information defined in domain.xml and the configuration information in the memory of the domain administration server are different.

Action

Take action appropriate for the message output trigger.

  • If the output trigger was the execution of the start-domain subcommand with the --upgrate option specified

    Remove the cause of the error, and then re-execute the subcommand.

  • For other output triggers

    Remove the cause of the error, and then use the get subcommand to obtain the attribute value. Execute set to set the obtained value. As a result, the configuration information in memory is applied to domain.xml. The following shows a command execution example:

    >asadmin get configs.config.default-config.hitachi-manage-info.start-timeout-in
    -seconds
    configs.config.default-config.hitachi-manage-info.start-timeout-in-seconds=60
    Command get executed successfully.
    >asadmin set configs.config.default-config.hitachi-manage-info.start-timeout-in
    -seconds=60