19101 <Information>

Flow control for the distribution function that uses Remote Install Manager is disabled.

Cause

Possible causes are as follows:

  • Failed to open the configuration file (jdn_rim_distr_bwc.conf).

  • The BandwidthCtrl section was not found in the configuration file.

  • The Function key was not found in the BandwidthCtrl section.

  • The Function key was not enabled for the BandwidthCtrl section.

  • There is no valid SettingN section.

Action
  • Make sure that the configuration file exists.

  • Make sure that the BandwidthCtrl section exists in the configuration file, and that the Function key is enabled.

  • Make sure that a valid SettingN section is present.

Note: If the relay system has enabled flow control for the distribution function using the Remote Install Manager, this message is output in the relay system's public log (MAIN.LOG). For relay system, replace "SettingN section" with "Setting section".