6.2.7 Return codes of service linkage objects monitoring jobs
The following table shows return codes when service linkage objects monitoring jobs are executed.
|
Return code |
Content |
Corresponding messages |
|---|---|---|
|
0 |
The monitoring condition is met. |
-- |
|
101 to 150 |
This is the return code set according to the definitions, if any, on the JP1/AJS3 for Cloud Service Applications server. |
KNBB6310-E |
|
151 |
The definition of the service linkage objects monitoring job contains an error. |
KNBB6102-E |
|
152 |
|
KNBB6309-E |
|
153 |
Failed to read the connection configuration file. |
KNBB6200-E |
|
154 |
The syntax in the connection configuration file has an error. |
KNBB6201-E |
|
155 |
Failed to resolve the name (IP address resolution) of the JP1/AJS3 for Cloud Service Applications server. |
KNBB6204-E |
|
156 |
An error occurred during access to the temporary file. |
KNBB6449-E |
|
170 |
Failed to connect to the JP1/AJS3 for Cloud Service Applications server. |
KNBB6202-E |
|
171 |
An error occurred in communication with the JP1/AJS3 for Cloud Service Applications server. |
KNBB6203-E |
|
172 |
The information obtained from the JP1/AJS3 for Cloud Service Applications server contains an error. |
KNBB6300-E |
|
173 |
A definition item for JP1/AJS3 for Cloud Service Applications has one of the following errors:
|
KNBB6100-E |
|
175 |
A definition of the service linkage objects monitoring job is inconsistent with the one on the JP1/AJS3 for Cloud Service Applications server.
|
KNBB6103-E |
|
176 |
An error occurred in the extraction processing of information from the execution result of the object list information acquisition command according to the JMESPath query syntax. |
KNBB6105-E |
|
177 |
The result extracted from the object list information is incorrect. |
KNBB6106-E |
|
178 |
The update monitoring target data extracted from the object list information is in valid format. |
KNBB6107-E |
|
180 |
Failed to obtain an environment variable. |
KNBB6400-E |
|
181 |
An error occurred in the command executed by the service linkage objects monitoring job. |
KNBB6311-E |
|
182 |
The command executed by the service linkage objects monitoring job has received a signal and ended. |
KNBB6312-E |
|
183 |
The size of the standard output for the command executed by the service linkage objects monitoring job exceeded the value of the LimitObjMonStdOutSize environment setting parameter. |
KNBB6306-E |
|
190 |
A memory shortage occurred. |
KNBB6450-E |
|
191 |
System error occurred. |
KNBB6451-E |
|
192 |
An unexpected error occurred. |
KNBB6452-E |
- Note
-
If you work with the entire start condition (when the start condition is forcibly terminated, for example) or if an error related to the entire start condition occurs, the return code of each event of the entire start condition is set to 0 (zero). On the other hand, if an error on a particular event occurs (when an error occurs due to an incorrect definition, for example), the return code shown in the table is set.