3.2.1 Installing a new instance
To install a new instance of CPA Option for AJS3:
-
As a member of the Administrators group, log in to the host on which you want to install CPA Option for AJS3.
-
Insert the CPA Option for AJS3 media.
The Hitachi integrated installer window appears.
-
Follow the instructions from the Hitachi integrated installer and specify information as necessary to install the software.
-
User name#1
Enter the Windows user name which uses CPA Option for AJS3. The length must not exceed 50 bytes.
-
Organization#1
Enter the name of your company or department. The length must not exceed 80 bytes.
-
Installation folder#2
Specify the absolute path to the folder in which you want to install CPA Option for AJS3. The length, including a backslash (\) that is automatically added to the end of the path, must not exceed 80 bytes. The absolute path must point to a local directory.
If you do not specify any value, the following value is assumed:
system-drive\Program Files (x86)\HITACHI\JP1CPA#3
-
Data Folder#2
Specify the absolute path to the folder in which you want to store CPA Option for AJS3 data. The length, including a backslash (\) that is automatically added to the end of the path, must not exceed 80 bytes. The absolute path must point to a local directory.
If you do not specify any value, the following value is assumed:
system-drive\ProgramData\HITACHI\jp1\jp1_default\JP1CPA
#1: Do not include the following characters in the user name or organization name:
- Symbols except for the following:
Space, left parenthesis ((), right parenthesis ()), plus sign (+), hyphen (-), and underscore (_)
#2: Ensure that the installation folder and data folder do not include the following characters or paths:
- Symbols except for the following:
Space, left parenthesis ((), right parenthesis ()), plus sign (+), hyphen (-), and underscore (_)
Note that you cannot include a space at the beginning or end of the path, before or after a backslash (\), or in succession with another space.
- Multibyte characters
- Paths to non-fixed drives or UNC paths
#3: If you are using a 32-bit operating system, replace Program Files (x86) with Program Files.
-
-
When the installation is completed, click the Finish button.
The following table lists default values for installation settings.
No. |
Setting |
Default value |
---|---|---|
1 |
Installation folder |
|
2 |
Data folder |
%ProgramData%\Hitachi\jp1\jp1_default\JP1CPA |
3 |
Service name of the job execution service |
JP1_CPA |
4 |
Service display name of the job execution service |
JP1/CPA |
5 |
Startup type of the job execution service |
Automatic (AUTO) |
6 |
Service name of the message communication service |
JP1_CPA_Message |
7 |
Service display name of the message communication service |
JP1/CPA Message |
8 |
Startup type of the message communication service |
Automatic (AUTO) |
9 |
Name of the program folder in the Start menu |
JP1_Client Process Automation |
10 |
Name of a shortcut in the Start menu to configure the firewall settings |
Enable firewall settings |
11 |
Name of a shortcut in the Start menu to revert the firewall settings |
Disable firewall settings |