KAJM0113-E
An attempt to load the RFC library failed. (file: file-name, reason: cause, function: function-name, maintenance code: maintenance-code)
An error occurred while the RFC library was being loaded.
The following information is output to individual items in the message:
-
file-name: Absolute path to the RFC library
-
cause: Text that indicates the cause of the error
no such file(s): The file or files do not exist.
invalid library(ies): The library or libraries are invalid.
the CRT libraries are not installed: The necessary CRT libraries are not installed.
system error: A system error occurred.
-
function-name: Name of the API of the OS in which the error occurred
-
maintenance-code: Error code returned from the API of the OS
- (S)
-
The system aborts command execution.
- (O)
-
For the RFC library that was output to file-name in the message, remove the cause that was output to cause in the message, and then execute the command again.
The following shows how to handle individual causes that can be output to cause in the message:
-
no such file(s)
Ensure that the RFC library obtained from the provider is located in the path that was output to file-name in the message. If any problem exists, follow the procedures described in 2.5 SAP NetWeaver RFC Library setup to locate the correct RFC library.
-
invalid library(ies)
Ensure that the RFC library that was output to file-name in the message is correct. (Ensure that the library corresponds to the OS and architecture of the running environment, and that the version of the library is the required version for operating the product.) If any problem exists, follow the procedures described in 2.5 SAP NetWeaver RFC Library setup to locate the correct RFC library.
-
the CRT libraries are not installed
Ensure that the C runtime library required for RFC library operation has been installed. If any problem exists, follow the procedures described in 2.5 SAP NetWeaver RFC Library setup to locate the correct C runtime library.
-
system error
Collect maintenance information, and then contact the system administrator.
If the problem still remains after performing the procedure above, collect the maintenance information, and then contact the system administrator.
For details about the version of the RFC library required for using the product and how to obtain the RFC library, see the product manual or Release Notes.
-