Hitachi

JP1 Version 13 JP1/Automatic Job Management System 3 Messages


KAVT0620-E

The subagent pipe could not be written to. (code=maintenance-code)

An attempt to write to a pipe file used in the event/action control subagent has failed.

(S)

Continues processing without changing the status of the unit (a jobnet with start conditions, an event job or a custom event job). If the jpoagtsub process is not running, the system terminates the event/action control subagent.

(O)

Check the following, making sure that the status of the unit (a jobnet with start conditions, an event job or a custom event job) has not changed, and then retry:

  • Check whether system resources are sufficient.

  • Check whether the user who started JP1/AJS3 has superuser privileges or administrator privileges.

  • Check whether the directory created at JP1/AJS3 installation was unintentionally deleted.

  • Use a command such as a ps command to check whether the jpoagtsub process is running. If it is not running, restart JP1/AJS3.