B.2 Using the default values for version 10-50 and earlier for customizable items whose default values have changed in version 11-00
This section describes how to use the original default values for version 10-50 and earlier with customizable items whose default values have changed in version 11-00.
- Organization of this subsection
(1) Items set in the user-specified option file
You can restore the original default values for customizable items by using the model file for the user-specified option file (ajs2view_opt.conf.V10.model) provided for version 10-50 and earlier.
To restore the default values to those used in version 10-50 and earlier:
-
Back up the user-specified option file to a location of your choice.
The user-specified option file is stored in the following folder:
%ALLUSERSPROFILE%\Hitachi\JP1\JP1_DEFAULT\JP1AJS2V\conf\JP1-user-name#
The default value of %ALLUSERSPROFILE% is system-drive\ProgramData.
- #
-
A folder is created for any JP1 user who has logged in at least once.
If you use any of the following names as a JP1 user name, the folder created for that JP1 user will be enclosed in single-byte parentheses (()):
- A device name such as NUL, CON, AUX, COM1 to COM9, LPT1 to LPT9, or PRN
- A name in the format device-name.extension
- A name that starts with a period (.)
-
Copy the model file for the user-specified option file in version 10-50 and earlier (ajs2view_opt.conf.V10.model) to the folder that contains the model file for the user-specified option file.
The ajs2view_opt.conf.V10.model file is stored in the following folder:
JP1/AJS3 - View-installation-folder\conf
-
Change the name of the copy of the ajs2view_opt.conf.V10.model file to ajs2view_opt.conf.
-
Start JP1/AJS3 - View.
Any instance of JP1/AJS3 - View started after you have replaced the user-specified option file will apply the default values for version 10-50 and earlier to customizable items.
(2) Items set in the Preferences dialog box
To restore the default value from version 10-50 and earlier for a customizable item whose default value in the Preferences dialog box has changed in version 11-00, change the corresponding value in the Preferences dialog box.