15.2.3 List screen

In the List screen, you can perform tasks such as monitoring units, setting hold attributes, and registering units for execution. Clicking the Dashboard tab displays the Dashboard screen.

You can also open the List screen from the Integrated Operation Viewer window of JP1/IM2.

The following figure shows the List screen.

Figure 15‒6: List screen

[Figure]

If automatic refresh is enabled, the List screen is refreshed every 10 minutes, starting from the time that automatic refresh is enabled. The automatic refresh interval can be changed in the Setting dialog box.

The List screen consists of two main areas:

Tree area

This area displays the units the logged-in JP1 user has permission to reference in tree format. When you select a job group in the tree area, the units under the selected job group appear in the list area.

List area

This area displays the units under the job group selected in the tree area.

You can manipulate a unit by selecting it in the list and clicking the buttons above the list. The following table describes the operations that can be performed by using these buttons.

Table 15‒3: Operations that can be performed by clicking the buttons in the List screen

No.

Button

Operation

1

Entry#

Displays the Register for Execution dialog box, allowing you to register the selected unit for execution.

2

Leave#

Displays the Cancel Registration dialog box, allowing you to unregister the selected unit for execution.

3

Status

Displays the Monitor dialog box, allowing you to check the current status of the selected unit.

4

Result

Displays the Monitor dialog box, allowing you to check the execution result of the selected unit.

5

Next

Displays the Monitor dialog box, allowing you to check when the selected unit will be executed next.

6

Monthly

Displays the Monthly Schedule screen.

#

If the operation restriction function of the job portal is enabled, these buttons appear only if the logged-in user is a user who is permitted to perform the corresponding operations.

Cautionary notes
  • The List screen can be opened from JP1/IM2 only if the relevant unit or generation exists.

  • If, for a certain length of time, no operations are performed in the List screen and the List screen is not refreshed, the session times out. If the session times out, an error message appears, and the web browser closes. The session timeout period for the job portal can be specified by using the environment setting file (ajs3web.conf). The default is 15 minutes. For details about the environment settings file (ajs3web.conf) in Windows, see 3.4.3 Details on the settings in the environment-settings file (ajs3web.conf) in the JP1/Automatic Job Management System 3 Configuration Guide. For details about the environment settings file (ajs3web.conf) in Linux, see 13.3.3 Details on settings in the environment-settings file (ajs3web.conf) in the JP1/Automatic Job Management System 3 Configuration Guide.

  • The following operations or events that usually cause the web browser to close, instead cause the Login screen being displayed:

    - Clicking the Log Out button or the Close button on the List screen.

    - An error that usually causes the web browser to close (such as an invalid session error).

  • The Login screen might not be displayed if an error occurs during the startup of the List screen. If the Login screen is not displayed, manually close the web browser.

List of screens that can be displayed from the List screen:

No.

Screen

Relevant section

1

Monthly Schedule screen

15.2.7

2

Monitor dialog box

15.2.8

3

Register for Execution dialog box

15.2.18

4

Register Passing Information dialog box

15.2.19

5

Variables Used dialog box

15.2.20

6

Cancel Registration dialog box

15.2.21

7

Setting dialog box

15.2.28

8

Apply Operating Permission Settings dialog box

15.2.29