25.8.3 NNMi Northbound interface destination status information
The following table lists the read-only status information for the Northbound destination. This information is useful for verifying that the integration is working correctly.
Field |
Description |
---|---|
Trap Destination IP Address |
The IP address to which the destination host name resolves. This value is unique to this Northbound destination. |
Uptime (seconds) |
The time (in seconds) since the Northbound component was last started. The traps that NNMi sends to a Northbound application include this value in the sysUptime field (1.3.6.1.2.1.1.3.0). This value is the same for all integrations that use the NNMi Northbound interface. To see the latest value, either refresh or close then re-open the form. |
NNMi URL |