Notes common to all functions
The notes common to all functions provided by JP1/Base are as follows.
-
For the Windows and UNIX versions, the operation of a function called from a multi-thread program is assured.
-
For the Windows and UNIX versions, when using the functions in a multi-thread program, you cannot use any of these functions in a thread that was generated before the first function was called.
-
If there is only one FQDN format event server name in the Event server index file for the JP1/Base physical host and you call the JP1 event acquisition function, add the definition of * (indicating that the event server name runs on local host) as event-server-name. (This works on JP1/Base version 12-10 or later.) Also, the directory name (with underlined) needs to be matched with the existing definition. The use of the product cannot be guaranteed unless the directory name is matched. Also, if the definition is not added, the JP1 event acquisition function fails.
Definition example of the event server index file
#----------------------------------------------------------------------- # JP1/Base - Event Server Index #----------------------------------------------------------------------- server hostX.d1.hitachi.co.jp default server * default