The connection with JP1/Base at the event-forwarding relay destination could not be established. (Address of the event-forwarding relay destination = event-forwarding-relay-destination-IP-address-and-port, host name at the event-forwarding relay source = host-name-at-the-event-forwarding-relay-source, maintenance information = maintenance-information)

Forwarding of the event failed because a communication error occurred while connecting imbase to event-forwarding relay destination JP1/Base.

S:

Continues processing. Events that fail to relay event forwarding are resent by JP1/Base.

O:

Because event forwarding is resent by JP1/Base, no action is required in the temporary failure.

If it occurs repeatedly, check the following points.

  • Is JP1/Base of event-forwarding relay destination running?

  • Is the value of the jp1base_forward_send.port of imbase configuration file (jpc_imbase.json) equal to port used for forwarding events in JP1/Base of event-forwarding relay destination?