Hitachi

uCosminexus Application Server Definition Reference Guide


A.1 Tables in the extended MIB object definition file

This section describes the tables of the extended MIB object definition file.

The OIDs of each table are as follows:

.iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).hitachi(116).systemExMib(5).cosminexusMibs(33).manager(1)

Organization of this subsection

(1) j2eeContainerTable

The following table describes j2eeContainerTable:

Table A‒1: j2eeContainerTable

Table name

(OID)

Entry name

(OID)

Metric name

(OID)

TYPE

R/W

Unit

Description

Preconditions

j2eeContainerTable

(1)

j2eeContainerEntry

(1)

j2eeContainerIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

None

j2eeContainerFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name"

j2eeContainerServerName

(3)

DisplayString

RO

--

Name of the J2EE server

j2eeContainerNamingServiceHost

(4)

DisplayString

RO

--

Host name of the Naming Service to which the J2EE server is to be connected.

j2eeContainerNamingServicePort

(5)

INTEGER

RO

--

Port number of the Naming Service to which the J2EE server is to be connected.

j2eeContainerStartedTime

(6)

INTEGER

RO

Seconds

Startup time of the J2EE server#

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

#

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

(2) jvmTable

The following table describes jvmTable:

Table A‒2: jvmTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

jvmTable

(2)

jvmEntry

(1)

jvmIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

None

jvmFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name"

jvmName

(3)

DisplayString

RO

--

Implementation name of JavaVM

jvmVersion

(4)

DisplayString

RO

--

Implementation version of JavaVM

jvmCurrentFreeMemory

(5)

Gauge

RO

KB

Free memory requirement of JavaVM (current value)

jvmFreeMemoryHighWaterMark

(6)

Gauge

RO

KB

Free memory requirement of JavaVM (maximum value)

jvmFreeMemoryLowWaterMark

(7)

Gauge

RO

KB

Free memory requirement of JavaVM (minimum value)

jvmFreeMemoryAverag

(8)

Gauge

RO

KB

Free memory requirement of JavaVM (average value#1)

jvmFreeMemoryPeak

(9)

Gauge

RO

KB

Free memory requirement of JavaVM (peak value#2)

jvmCurrentTotalMemory

(10)

Gauge

RO

KB

Current value of the total memory requirement of JavaVM (total of the used memory requirement and free memory requirement)

jvmTotalMemoryHighWaterMark

(11)

Gauge

RO

KB

Maximum value of the total memory requirement of JavaVM (total of the used memory requirement and free memory requirement)

jvmTotalMemoryLowWaterMark

(12)

Gauge

RO

KB

Minimum value of the total memory requirement of JavaVM (total of the used memory requirement and free memory requirement)

jvmTotalMemoryAverage

(13)

Gauge

RO

KB

Average value#1 of the total memory requirement of JavaVM (total of the used memory requirement and free memory requirement)

jvmTotalMemoryPeak

(14)

Gauge

RO

KB

Peak value#2 of the total memory requirement of JavaVM (total of the used memory requirement and free memory requirement)

jvmMaxMemory

(15)

INTEGER

RO

KB

If maximum used memory requirement of JavaVM

is not specified, assume (263-1)/210

jvmStatisticsStartedTime

(16)

INTEGER

RO

Seconds

Statistics start time#3

jvmSamplingTime

(17)

INTEGER

RW

Seconds

Statistics sampling time#4

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Peak value at the point of value acquisition request

This peak value is the maximum value for the available period of the sampling time after recording.

#3

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#4

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(3) transactionTable

The following table describes transactionTable:

Table A‒3: transactionTable

Table name

(OID)

Entry name

(OID)

Metric name

(OID)

TYPE

R/W

Unit

Description

Preconditions

transactionTable

(3)

transactionEntry

(1)

transactionIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The transaction must be started

transactionFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name"

transactionDefaultTransactionTimeout

(3)

INTEGER

RO

Seconds

Default value of transaction timeout

transactionActiveTransactionCount

(4)

Gauge

RO

--

Number of active transactions (current value)

transactionAveTime

(5)

Gauge

RO

Milliseconds

Transaction time (average value#1)

transactionStatisticsStartedTime

(6)

INTEGER

RO

Seconds

Statistics start time#2

transactionSamplingTime

(7)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(4) httpServerTable

The following table describes httpServerTable:

Table A‒4: httpServerTable

Table name

(OID)

Entry name

(OID)

Metric name

(OID)

TYPE

R/W

Unit

Description

Preconditions

httpServerTable

(4)

httpServerEntry

(1)

httpServerIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

None

httpServerFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name"

httpServerPortNumber

(3)

INTEGER

RO

--

Port number of the server for management

httpServerActiveThreadCountHighWaterMark

(4)

Gauge

RO

--

Number of active threads (maximum value)

httpServerActiveThreadCountLowWaterMark

(5)

Gauge

RO

--

Number of active threads (minimum value)

httpServerActiveThreadCountAverage

(6)

Gauge

RO

--

Number of active threads (average value#1)

httpServerActiveThreadCountPeak

(7)

Gauge

RO

--

Number of active threads (peak value#2)

httpServerStatisticsStartedTime

(8)

INTEGER

RO

Seconds

Statistics start time#3

httpServerSamplingTime

(9)

INTEGER

RW

Seconds

Statistics sampling time#4

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Peak value at the point of value acquisition request

This peak value is the maximum value for the available period of the sampling time after recording.

#3

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#4

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(5) httpServerConnectorTable

The following table describes httpServerConnectorTable:

Table A‒5: httpServerConnectorTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

httpServer

ConnectorTable

(5)

httpServer

ConnectorEntry

(1)

httpServerConnectorIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Web server integration functionality is used

httpServerConnectorFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name"

httpServerConnectorPortNumber

(3)

INTEGER

RO

--

Port used for communication with the Web server

httpServerConnectorBackLogUpperBound

(4)

INTEGER

RO

--

Backlog of the socket used for communication with the Web server

httpServerConnectorConnectionCount

(5)

Gauge

RO

--

Number of connections between the Web server and Web container (current value)

httpServerConnectorConnectionCountHighWaterMark

(6)

Gauge

RO

--

Number of connections between the Web server and Web container (maximum value)

httpServerConnectorConnectionCountLowWaterMark

(7)

Gauge

RO

--

Number of connections between the Web server and Web container (minimum value)

httpServerConnectorActiveThreadCountUpperBound

(8)

Gauge

RO

--

Number of active threads (upper-limit value)

httpServerConnectorActiveThreadCountHighWaterMark

(9)

Gauge

RO

--

Number of active threads (maximum value)

httpServerConnectorActiveThreadCountLowWaterMark

(10)

Gauge

RO

--

Number of active threads (minimum value)

httpServerConnectorActiveThreadCountAverage

(11)

Gauge

RO

--

Number of active threads (average value#1)

httpServerConnectorActiveThreadCountPeak

(12)

Gauge

RO

--

Number of active threads (peak value#2)

httpServerConnectorWaitingRequestCountHighWaterMark

(13)

Gauge

RO

--

Number of requests awaiting execution based on the upper-limit value set for the running threads (maximum value)

httpServerConnectorWaitingRequestCountLowWaterMark

(14)

Gauge

RO

--

Number of requests awaiting execution based on the upper-limit value set for the running threads (minimum value)

httpServerConnectorWaitingRequestCountAverage

(15)

Gauge

RO

--

Number of requests awaiting execution based on the upper-limit value set for the running threads (average value#1)

httpServerConnectorWaitingRequestCountPeak

(16)

Gauge

RO

--

Number of requests awaiting execution based on the upper-limit value set for the running threads (peak value#2)

httpServerConnectorStatisticsStartedTime

(17)

INTEGER

RO

Seconds

Statistics start time#3

httpServerConnectorSamplingTime

(18)

INTEGER

RW

Seconds

Statistics sampling time#4

httpServerConnectorActiveThreadCount

(19)

Gauge

RO

--

Number of active threads

httpServerConnectorWaitingRequestCount

(20)

Gauge

RO

--

Number of requests awaiting execution

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Peak value at the point of value acquisition request

This peak value is the maximum value for the available period of the sampling time after recording.

#3

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#4

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(6) dataSourceTable

The following table describes dataSourceTable:

Table A‒6: dataSourceTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

dataSourceTable

(6)

dataSourceEntry

(1)

dataSourceIndex(1)

INTEGER

RO

--

Sequence number [1,...]

The data source must be imported

dataSourceFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:data-source-name"

dataSourceName

(3)

DisplayString

RO

--

Data source name

dataSourceAuthenticationType

(4)

INTEGER

RO

--

Authentication type

0: Authentication of each application

1: Authentication of each container

dataSourceLoginTimeout

(5)

INTEGER

RO

Seconds

Login timeout value

dataSourceUserID

(6)

DisplayString

RO

--

User ID

dataSourcePoolUpperBound

(7)

INTEGER

RO

--

Number of connection pools (upper-limit value)

dataSourcePoolLowerBound

(8)

INTEGER

RO

--

Number of connection pools (lower-limit value)

dataSourceCurrentPoolSize

(9)

Gauge

RO

--

Number of connection pools (current value)

dataSourceActiveConnectionCount

(10)

Gauge

RO

--

Number of active connections (current value)

dataSourceFreeConnectionCount

(11)

Gauge

RO

--

Number of free connections (current value)

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

(7) j2eeApplicationTable

The following table describes j2eeApplicationTable:

Table A‒7: j2eeApplicationTable

Table name

(OID)

Entry name

(OID)

Metric name

(OID)

TYPE

R/W

Unit

Description

Preconditions

j2eeApplicationTable

(7)

j2eeApplicationEntry

(1)

j2eeApplicationIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The J2EE application (EAR) must be started

j2eeApplicationFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name"#

j2eeApplicationName

(3)

DisplayString

RO

--

J2EE application name

j2eeApplicationDeployedTime

(4)

INTEGER

RO

Seconds

Time of deployment

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

#

When you start an application in the test mode,

the fully qualified name becomes"logical-server-name:J2EE-application-name_TEST".

(8) ejbApplicationTable

The following table describes ejbApplicationTable:

Table A‒8: ejbApplicationTable

Table name

(OID)

Entry name

(OID)

Metric name

(OID)

TYPE

R/W

Unit

Description

Preconditions

ejbApplicationTable

(8)

ejbApplicationEntry

(1)

ejbApplicationIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The EJB application (EJB-JAR) must be started

ejbApplicationFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name"

ejbApplicationName

(3)

DisplayString

RO

--

EJB application name (EJB-JAR name)

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

(9) statelessSessionBeanTable

The following table describes statelessSessionBeanTable:

Table A‒9: statelessSessionBeanTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

statelessSessionBeanTable

(9)

statelessSessionBeanEntry

(1)

statelessSessionBeanIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

A Stateless Session Bean is used

statelessSessionBeanFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

statelessSessionBeanName

(3)

DisplayString

RO

--

Enterprise Bean name

statelessSessionBeanHomeInterfaceName

(4)

DisplayString

RO

--

RemoteHome interface class name#1

statelessSessionBeanRemoteInterfaceName

(5)

DisplayString

RO

--

RemoteComponent interface class name#1

statelessSessionBeanLocalHomeInterfaceName

(6)

DisplayString

RO

--

LocalHome interface class name (EJB2.0 compliant)#2

statelessSessionBeanLocalComponentInterfaceName

(7)

DisplayString

RO

--

LocalComponent interface class name (EJB2.0 compliant)#2

statelessSessionBeanEjbClassName

(8)

DisplayString

RO

--

EJB class name

statelessSessionBeanPoolUpperBound

(9)

INTEGER

RO

--

Number of instance pools (upper-limit value)

statelessSessionBeanPoolLowerBound

(10)

INTEGER

RO

--

Number of instance pools (lower-limit value)

statelessSessionBeanCurrentPoolSize

(11)

Gauge

RO

--

Number of instance pools (current value)

statelessSessionBeanWaitingSessionCount

(12)

Gauge

RO

--

Number of sessions waiting to be connected (current value)

statelessSessionBeanActiveSessionBeanCount

(13)

Gauge

RO

--

Number of active Stateless Session Beans (current value)

statelessSessionBeanFreeSessionBeanCount

(14)

Gauge

RO

--

Number of free Stateless Session Beans (current value)

statelessSessionBeanFreeSessionTransactionType

(15)

DisplayString

RO

--

Transaction type

"CMT" or "BMT"

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

#1

Displays "" (a null character) only in case of the Local interface.

#2

Displays "" (a null character) only in case of the Remote interface.

(10) statelessSessionBeanHomeTable

The following table describes statelessSessionBeanHomeTable:

Table A‒10: statelessSessionBeanHomeTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

statelessSession

BeanHomeTable

(10)

statelessSession

BeanHomeEntry

(1)

statelessSessionBeanHomeIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateless Session Bean Remote Home Interface is used

statelessSessionBeanHomeFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

statelessSessionBeanHomeName

(3)

DisplayString

RO

--

RemoteHome interface class name

statelessSessionBeanHomeResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the RemoteHome interface (maximum value)

statelessSessionBeanHomeResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the RemoteHome interface (minimum value)

statelessSessionBeanHomeResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the RemoteHome interface (average value#1)

statelessSessionBeanHomeStatisticsStartedTime

(7)

INTEGER

RO

Seconds

Statistics start time#2

statelessSessionBeanHomeSamplingTime

(8)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(11) statelessSessionBeanRemoteTable

The following table describes statelessSessionBeanRemoteTable:

Table A‒11: statelessSessionBeanRemoteTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

statelessSession

BeanRemoteTable

(11)

statelessSession

BeanRemoteEntry

(1)

statelessSessionBeanRemoteIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateless Session Bean Remote Component Interface is used

statelessSessionBeanRemoteFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

statelessSessionBeanRemoteName

(3)

DisplayString

RO

--

RemoteComponent interface class name

statelessSessionBeanRemoteResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the RemoteComponent interface (maximum value)

statelessSessionBeanRemoteResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the RemoteComponent interface (minimum value)

statelessSessionBeanRemoteResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the RemoteComponent interface (average value#1)

statelessSessionBeanRemoteResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Remote interface (maximum value)

statelessSessionBeanRemoteResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Remote interface (minimum value)

statelessSessionBeanRemoteResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Remote interface (average value#1)

statelessSessionBeanRemoteStatisticsStartedTime

(10)

INTEGER

RO

Seconds

Statistics start time#2

statelessSessionBeanRemoteSamplingTime

(11)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(12) statefulSessionBeanTable

The following table describes statefulSessionBeanTable:

Table A‒12: statefulSessionBeanTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

statefulSession

BeanTable

(12)

statefulSession

BeanEntry

(1)

statefulSessionBeanIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

A Stateful Session Bean is used

statefulSessionBeanFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

statefulSessionBeanName

(3)

DisplayString

RO

--

Enterprise Bean name

statefulSessionBeanHomeInterfaceName

(4)

DisplayString

RO

--

RemoteHome interface class name#1

statefulSessionBeanRemoteInterfaceName

(5)

DisplayString

RO

--

RemoteComponent interface class name#1

statefulSessionBeanLocalHomeInterfaceName

(6)

DisplayString

RO

--

LocalHome interface class name#2

statefulSessionBeanLocalComponentInterfaceName

(7)

DisplayString

RO

--

LocalComponent interface class name#2

statefulSessionBeanEjbClassName

(8)

DisplayString

RO

--

EJB class name

statefulSessionBeanSessionUpperBound

(9)

INTEGER

RO

--

Number of concurrent connections (upper-limit value)

statefulSessionBeanActiveSessionUpperBound

(10)

INTEGER

RO

--

Number of concurrent executions (upper-limit value)

statefulSessionBeanPassivateTimeout

(11)

INTEGER

RO

Seconds

Timeout value of a passive session

statefulSessionBeanActiveTimeout

(12)

INTEGER

RO

Seconds

Timeout value of an active session

statefulSessionBeanCurrentSessionCount

(13)

Gauge

RO

--

Number of connected sessions (current value)

statefulSessionBeanWaitingSessionCount

(14)

Gauge

RO

--

Number of sessions waiting to be connected (current value)

statefulSessionBeanActiveSessionCount

(15)

Gauge

RO

--

Number of active sessions (current value)

statefulSessionBeanPassiveSessionCount

(16)

Gauge

RO

--

Number of passive sessions (current value)

statefulSessionBeanTransactionType

(17)

DisplayString

RO

--

Transaction type

"CMT" or "BMT"

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

#1

Displays "" (a null character) only in case of the Local interface.

#2

Displays "" (a null character) only in case of the Remote interface.

(13) statefulSessionBeanHomeTable

The following table describes statefulSessionBeanHomeTable:

Table A‒13: statefulSessionBeanHomeTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

statefulSession

BeanHomeTable

(13)

statefulSession

BeanHomeEntry

(1)

statefulSessionBeanHomeIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

Stateful Session Bean Remote Home Interface is used

statefulSessionBeanHomeFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

statefulSessionBeanHomeName

(3)

DisplayString

RO

--

RemoteHome interface class name

statefulSessionBeanHomeResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the RemoteHome interface (maximum value)

statefulSessionBeanHomeResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the RemoteHome interface (minimum value)

statefulSessionBeanHomeResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the RemoteHome interface (average value#1)

statefulSessionBeanHomeResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the RemoteHome interface (maximum value)

statefulSessionBeanHomeResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the RemoteHome interface (minimum value)

statefulSessionBeanHomeResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the RemoteHome interface (average value#1)

statefulSessionBeanHomeStatisticsStartedTime

(10)

INTEGER

RO

Seconds

Statistics start time#2

statefulSessionBeanHomeSamplingTime

(11)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(14) statefulSessionBeanRemoteTable

The following table describes statefulSessionBeanRemoteTable:

Table A‒14: statefulSessionBeanRemoteTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

statefulSession

BeanRemoteTable

(14)

statefulSession

BeanRemoteEntry

(1)

statefulSessionBeanRemoteIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateful Session Bean Remote Component Interface is used

statefulSessionBeanRemoteFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

statefulSessionBeanRemoteName

(3)

DisplayString

RO

--

RemoteComponent interface class name

statefulSessionBeanRemoteResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the RemoteComponent interface (maximum value)

statefulSessionBeanRemoteResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the RemoteComponent interface (minimum value)

statefulSessionBeanRemoteResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the RemoteComponent interface (average value#1)

statefulSessionBeanRemoteResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the RemoteComponent interface (maximum value)

statefulSessionBeanRemoteResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the RemoteComponent interface (minimum value)

statefulSessionBeanRemoteResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the RemoteComponent interface (average value#1)

statefulSessionBeanRemoteStatisticsStartedTime

(10)

INTEGER

RO

Seconds

Statistics start time#2

statefulSessionBeanRemoteSamplingTime

(11)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(15) entityBeanTable

The following table describes entityBeanTable:

Table A‒15: entityBeanTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

entityBeanTable

(15)

entityBeanEntry

(1)

entityBeanIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

An Entity Bean is used

entityBeanFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

entityBeanName

(3)

DisplayString

RO

--

Enterprise Bean name

entityBeanHomeInterfaceName

(4)

DisplayString

RO

--

RemoteHome interface class name#1

entityBeanRemoteInterfaceName

(5)

DisplayString

RO

--

RemoteComponent interface class name#1

entityBeanLocalHomeInterfaceName

(6)

DisplayString

RO

--

LocalHome interface class name#2

entityBeanLocalComponentInterfaceName

(7)

DisplayString

RO

--

LocalComponent interface class name#2

entityBeanEjbClassName

(8)

DisplayString

RO

--

EJB class name

entityBeanPersistenceType

(9)

DisplayString

RO

--

Persistence type

CMP or BMP

entityBeanCacheOption

(10)

DisplayString

RO

--

Cache model

A: Full Cache

B: Cache

C: No Cache

entityBeanSessionUpperBound

(11)

INTEGER

RO

--

Number of concurrent connections (upper-limit value)

entityBeanPoolUpperBound

(12)

INTEGER

RO

--

Number of instance pools (upper-limit value)

entityBeanPoolLowerBound

(13)

INTEGER

RO

--

Number of instance pools (lower-limit value)

entityBeanCurrentPoolSize

(14)

Gauge

RO

--

Number of instance pools (current value)

entityBeanSessionTimeout

(15)

INTEGER

RO

--

Connection timeout value

entityBeanCurrentSessionCount

(16)

Gauge

RO

--

Number of connected sessions (current value)

entityBeanWaitingSessionCount

(17)

Gauge

RO

--

Number of sessions waiting to be connected (current value)

entityBeanActiveEntityBeanCount

(18)

Gauge

RO

--

Number of active Entity Beans (current value)

entityBeanFreeEntityBeanCount

(19)

Gauge

RO

--

Number of free Entity Beans (current value)

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

#1

Displays "" (a null character) only in case of the Local interface.

#2

Displays "" (a null character) only in case of the Remote interface.

(16) entityBeanHomeTable

The following table describes entityBeanHomeTable:

Table A‒16: entityBeanHomeTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

entityBeanHomeTable

(16)

entityBeanHomeEntry

(1)

entityBeanHomeIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Entity Bean Remote Home Interface is used

entityBeanHomeFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

entityBeanHomeName

(3)

DisplayString

RO

--

RemoteHome interface class name

entityBeanHomeResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the RemoteHome interface (maximum value)

entityBeanHomeResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the RemoteHome interface (minimum value)

entityBeanHomeResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the RemoteHome interface (average value#1)

entityBeanHomeResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the RemoteHome interface (maximum value)

entityBeanHomeResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the RemoteHome interface (minimum value)

entityBeanHomeResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the RemoteHome interface (average value#1)

entityBeanHomeStatisticsStartedTime

(10)

INTEGER

RO

Seconds

Statistics start time#2

entityBeanHomeSamplingTime

(11)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(17) entityBeanRemoteTable

The following table describes entityBeanRemoteTable:

Table A‒17: entityBeanRemoteTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

entityBeanRemoteTable

(17)

entityBeanRemoteEntry

(1)

entityBeanRemoteIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Entity Bean Remote Component Interface is used

entityBeanRemoteFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

entityBeanRemoteName

(3)

DisplayString

RO

--

RemoteComponent interface class name

entityBeanRemoteResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the RemoteComponent interface (maximum value)

entityBeanRemoteResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the RemoteComponent interface (minimum value)

entityBeanRemoteResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the RemoteComponent interface (average value#1)

entityBeanRemoteResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the RemoteComponent interface (maximum value)

entityBeanRemoteResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the RemoteComponent interface (minimum value)

entityBeanRemoteResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the RemoteComponent interface (average value#1)

entityBeanRemoteStatisticsStartedTime

(10)

INTEGER

RO

Seconds

Statistics start time#2

entityBeanRemoteSamplingTime

(11)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(18) webApplicationTable

The following table describes webApplicationTable:

Table A‒18: webApplicationTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

webApplicationTable

(18)

webApplicationEntry

(1)

webApplicationIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

A Web application (WAR) is used

webApplicationFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:Context-root"

webApplicationContextRoot

(3)

DisplayString

RO

--

Context root

webApplicationActiveSessionCount

(4)

Gauge

RO

--

Number of active sessions (current value)

webApplicationTotalJSPServiceCount

(5)

Counter

RO

--

Number of JSP executions (total value)

webApplicationTotalJSPServiceFailedCount

(6)

Counter

RO

--

Number of failed JSP executions (total value)

webApplicationTotalJSPServiceMaxTime

(7)

Gauge

RO

Milliseconds

JSP execution time (maximum value)

webApplicationTotalJSPServiceMinTime

(8)

Gauge

RO

Milliseconds

JSP execution time (minimum value)

webApplicationTotalJSPServiceAveTime

(9)

Gauge

RO

Milliseconds

JSP execution time (average value#1)

webApplicationTotalJSPServicePeak

(10)

Gauge

RO

Milliseconds

JSP execution time (peak value#2)

webApplicationTotalJSPServiceOutputDataSizeMax

(11)

Gauge

RO

KB

JSP output data size (maximum value)

webApplicationTotalJSPServiceOutputDataSizeMin

(12)

Gauge

RO

KB

JSP output data size (minimum value)

webApplicationTotalJSPServiceOutputDataSizeAve

(13)

Gauge

RO

KB

JSP output data size (average value#1)

webApplicationTotalJSPServiceOutputDataSizePeak

(14)

Gauge

RO

KB

JSP output data size (peak value#2)

webApplicationTotalStaticFileServiceCount

(15)

Counter

RO

--

Number of times of accessing static contents (total value)

webApplicationTotalStaticFileServiceFailedCount

(16)

Counter

RO

--

Number of times of accessing failed static contents (total value)

webApplicationTotalStaticFileServiceMaxTime

(17)

Gauge

RO

Milliseconds

Processing time for static contents acquisition (maximum value)

webApplicationTotalStaticFileServiceMinTime

(18)

Gauge

RO

Milliseconds

Processing time for static contents acquisition (minimum value)

webApplicationTotalStaticFileServiceAveTime

(19)

Gauge

RO

Milliseconds

Processing time for static contents acquisition (average value#1)

webApplicationTotalStaticFileServicePeak

(20)

Gauge

RO

Milliseconds

Processing time for static contents acquisition (peak value#2)

webApplicationTotalStaticFileServiceOutputDataSizeMax

(21)

Gauge

RO

KB

Static contents output data size (maximum value)

webApplicationTotalStaticFileServiceOutputDataSizeMin

(22)

Gauge

RO

KB

Static contents output data size (minimum value)

webApplicationTotalStaticFileServiceOutputDataSizeAve

(23)

Gauge

RO

KB

Static contents output data size (average value#1)

webApplicationTotalStaticFileServiceOutputDataSizePeak

(24)

Gauge

RO

KB

Static contents output data size (peak value#2)

webApplicationStatisticsStartedTime

(25)

INTEGER

RO

Seconds

Statistics start time#3

webApplicationSamplingTime

(26)

INTEGER

RW

Seconds

Statistics sampling time#4

webApplicationExclusiveThreadCountUpperBound

(27)

INTEGER

RO

--

Number of exclusive threads

  • A Web application (WAR) is used

  • The control functionality for concurrently executing threads is used

webApplicationActiveThreadCountUpperBound

(28)

INTEGER

RO

--

Number of active threads (upper-limit value)

webApplicationCurrentThreadCountUpperBound

(29)

Gauge

RO

--

Number of active threads (current upper-limit value#5)

webApplicationActiveThreadCount

(30)

Gauge

RO

--

Number of active threads (current value)

webApplicationActiveThreadCountHighWaterMark

(31)

Gauge

RO

--

Number of active threads (maximum value)

webApplicationActiveThreadCountLowWaterMark

(32)

Gauge

RO

--

Number of active threads (minimum value)

webApplicationActiveThreadCountAverage

(33)

Gauge

RO

--

Number of active threads (average value#1)

webApplicationActiveThreadCountPeak

(34)

Gauge

RO

--

Number of active threads (peak value#2)

webApplicationWaitingRequestCountUpperBound

(35)

INTEGER

RO

--

Number of requests awaiting execution based on the upper-limit value set for the running threads (upper-limit value)

webApplicationWaitingRequestCount

(36)

Gauge

RO

--

Number of requests awaiting execution based on the upper-limit value set for the running threads (current value)

webApplicationWaitingRequestCountHighWaterMark

(37)

Gauge

RO

--

Number of requests awaiting execution based on the upper-limit value set for the running threads (maximum value)

webApplicationWaitingRequestCountLowWaterMark

(38)

Gauge

RO

--

Number of requests awaiting execution based on the upper-limit value set for the running threads (minimum value)

webApplicationWaitingRequestCountAverage

(39)

Gauge

RO

--

Number of requests awaiting execution based on the upper-limit value set for the running threads (average value#1)

webApplicationWaitingRequestCountPeak

(40)

Gauge

RO

--

Number of requests awaiting execution based on the upper-limit value set for the running threads (peak value#2)

webApplicationOverflowRequestCount

(41)

Counter

RO

--

Number of requests for which an error is returned based on the upper limit value that is set up for pending requests of each URL group and Web application (total value)

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Peak value at the point of value acquisition request

This peak value is the maximum value for the available period of the sampling time after recording.

#3

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#4

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

#5

Upper-limit value for the number of threads that can be concurrently executed at present

(19) servletTable

The following table describes servletTable:

Table A‒19: servletTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

servletTable

(19)

servletEntry

(1)

servletIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

A servlet is used

servletFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:context-root:Servlet-class-name"

servletName

(3)

DisplayString

RO

--

Servlet name coded in web.xml

Null character if the servlet name is not set

servletServletClassName

(4)

DisplayString

RO

--

Servlet class name

servletServiceCount

(5)

Counter

RO

--

Number of executions of the servlet (total value)

servletServiceFailedCount

(6)

Counter

RO

--

Number of failed executions of the servlet (total value)

servletServiceMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the servlet (maximum value)

servletServiceMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the servlet (minimum value)

servletServiceAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the servlet (average value#1)

servletServicePeak

(10)

Gauge

RO

Milliseconds

Execution time of the servlet (peak value#2)

servletServiceOutputDataSizeMax

(11)

Gauge

RO

KB

Servlet output data size (maximum value)

servletServiceOutputDataSizeMin

(12)

Gauge

RO

KB

Servlet output data size (minimum value)

servletServiceOutputDataSizeAve

(13)

Gauge

RO

KB

Servlet output data size (average value#1)

servletServiceOutputDataSizePeak

(14)

Gauge

RO

KB

Servlet output data size (peak value#2)

servletStatisticsStartTime

(15)

INTEGER

RO

Seconds

Statistics start time#3

servletSamplingTime

(16)

INTEGER

RW

Seconds

Statistics sampling time#4

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Peak value at the point of value acquisition request

This peak value is the maximum value for the available period of the sampling time after recording.

#3

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#4

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(20) requestUrlTable

The following table describes requestUrlTable:

Table A‒20: requestUrlTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

requestUrlTable

(20)

requestUrlEntry

(1)

requestUrlIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

Statistics of the requestUrl must be started, and the URL for the corresponding Web application must be accessed

requestUrlFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:context-root:request-URL"

requestUrl

(3)

DisplayString

RO

--

Request URL

requestUrlServiceCount

(4)

Counter

RO

--

Number of request executions (total value)

requestUrlServiceFailedCount

(5)

Counter

RO

--

Number of failed request executions (total value)

requestUrlServiceMaxTime

(6)

Gauge

RO

Milliseconds

Request execution time (maximum value)

requestUrlServiceMinTime

(7)

Gauge

RO

Milliseconds

Request execution time (minimum value)

requestUrlServiceAveTime

(8)

Gauge

RO

Milliseconds

Request execution time (average value#1)

requestUrlServicePeak

(9)

Gauge

RO

Milliseconds

Request execution time (peak value#2)

requestUrlServiceOutputDataSizeMax

(10)

Gauge

RO

KB

Request output data size (maximum value)

requestUrlServiceOutputDataSizeMin

(11)

Gauge

RO

KB

Request output data size (minimum value)

requestUrlServiceOutputDataSizeAve

(12)

Gauge

RO

KB

Request output data size (average value#1)

requestUrlServiceOutputDataSizePeak

(13)

Gauge

RO

KB

Request output data size (peak value#2)

requestUrlStatisticsStartedTime

(14)

INTEGER

RO

Seconds

Statistics start time#3

requestUrlSamplingTime

(15)

INTEGER

RW

Seconds

Statistics sampling time#4

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Peak value at the point of value acquisition request

This peak value is the maximum value for the available period of the sampling time after recording.

#3

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#4

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(21) dataSourceFullJTATable

The following table describes dataSourceFullJTATable:

Table A‒21: dataSourceFullJTATable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

dataSourceFullJTATable

(21)

dataSourceFullJTAEntry

(1)

dataSourceFullJTAIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

Data source (XA) is imported

dataSourceFullJTAFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:data-source-name"

dataSourceFullJTAName

(3)

DisplayString

RO

--

Data source name

dataSourceFullJTALoginTimeout

(4)

INTEGER

RO

Seconds

Login timeout value

dataSourceFullJTAUserID

(5)

DisplayString

RO

--

User ID

dataSourceFullJTAPoolUpperBound

(6)

INTEGER

RO

--

Number of connection pools (upper-limit value)

dataSourceFullJTAPoolLowerBound

(7)

INTEGER

RO

--

Number of connection pools (lower-limit value)

dataSourceFullJTACurrentPoolSize

(8)

Gauge

RO

--

Number of connection pools (current value)

dataSourceFullJTAActiveConnectionCount

(9)

Gauge

RO

--

Number of active connections (current value)

dataSourceFullJTAFreeConnectionCount

(10)

Gauge

RO

--

Number of free connections (current value)

dataSourceFullJTAGetConnectionMaxTime

(11)

Gauge

RO

Milliseconds

Execution time of the getConnection method (maximum value)

dataSourceFullJTAGetConnectionMinTime

(12)

Gauge

RO

Milliseconds

Execution time of the getConnection method (minimum value)

dataSourceFullJTAGetConnectionAveTime

(13)

Gauge

RO

Milliseconds

Execution time of the getConnection method (average value#1)

dataSourceFullJTACreateConnectionMaxTime

(14)

Gauge

RO

Milliseconds

Execution time of the getXAConnection method (maximum value)

dataSourceFullJTACreateConnectionMinTime

(15)

Gauge

RO

Milliseconds

Execution time of the getXAConnection method (minimum value)

dataSourceFullJTACreateConnectionAveTime

(16)

Gauge

RO

Milliseconds

Execution time of the getXAConnection method (average value#1)

dataSourceFullJTAGetConnectionFailedCount

(17)

Counter

RO

--

Number of failures of the getConnection method

dataSourceFullJTAConnectionErrorCount

(18)

Counter

RO

--

Number of times a FATAL error occurred in the Connection.

Number of times the connectionErrorOccurred method of ConnectionEventListener was invoked.

dataSourceFullJTAStatisticsStartedTime

(19)

INTEGER

RO

Seconds

Statistics start time#2

dataSourceFullJTASamplingTime

(20)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(22) resourceAdapterTable

The following table describes resourceAdapterTable:

Table A‒22: resourceAdapterTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

resourceAdapterTable

(22)

resourceAdapterEntry

(1)

resourceAdapterIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

A resource adapter is used

resourceAdapterFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:resource-adapter-name":container

"logical-server-name:J2EE-application-name:resource-adapter-name":application"

resourceAdapterName

(3)

DisplayString

RO

--

Resource adapter name

resourceAdapterVendorName

(4)

DisplayString

RO

--

Name of the vendor providing the resource adapter

resourceAdapterSpecVersion

(5)

DisplayString

RO

--

Used version of the JCA-based resource adapter

resourceAdapterEISType

(6)

DisplayString

RO

--

EIS type to which the resource adapter connects

resourceAdapterVersion

(7)

DisplayString

RO

--

Version of the resource adapter

resourceAdapterConnectionFactoryInterfaceName

(8)

DisplayString

RO

--

Interface class name of ConnectionFactory

resourceAdapterConnectionFactoryImplName

(9)

DisplayString

RO

--

Implementation class name of ConnectionFactory

resourceAdapterManagedConnectionFactoryImplName

(10)

DisplayString

RO

--

Implementation class name of ManagedConnectionFactory

resourceAdapterConnectionInterfaceName

(11)

DisplayString

RO

--

Interface class name of Connection

resourceAdapterConnectionImplName

(12)

DisplayString

RO

--

Implementation class name of Connection

resourceAdapterTransactionSupport

(13)

DisplayString

RO

--

Supported transaction models

NoTransaction: No transaction

LocalTransaction: Local transaction

XATransaction: XA transaction

resourceAdapterConfigProperties

(14)

DisplayString

RO

--

ConfigurationProperty information#1

resourceAdapterMConCreateCount

(15)

Counter

RO

--

Number of executions of the createManagedConnection method of ManagedConnectionFactory

resourceAdapterConCreateCount

(16)

Counter

RO

--

Number of executions of the getConnection method of ManagedConnection

resourceAdapterMConCleanupCount

(17)

Counter

RO

--

Number of executions of the cleanup method of ManagedConnection

resourceAdapterMConDestroyCount

(18)

Counter

RO

--

Number of executions of the destroy method of ManagedConnection

resourceAdapterUserId

(19)

DisplayString

RO

--

User ID

resourceAdapterPoolUpperBound

(20)

INTEGER

RO

--

Number of connection pools (upper-limit value)

resourceAdapterPoolLowerBound

(21)

INTEGER

RO

--

Number of connection pools (lower-limit value)

resourceAdapterCurrentPoolSize

(22)

Gauge

RO

--

Number of connection pools (current value)

resourceAdapterActiveConnectionCount

(23)

Gauge

RO

--

Number of active connections (current value)

resourceAdapterFreeConnectionCount

(24)

Gauge

RO

--

Number of free connections (current value)

resourceAdapterGetConnectionMaxTime

(25)

Gauge

RO

Milliseconds

Execution time of the allocateConnection method of ConnectionManager (maximum value)

resourceAdapterGetConnectionMinTime

(26)

Gauge

RO

Milliseconds

Execution time of the allocateConnection method of ConnectionManager (minimum value)

resourceAdapterGetConnectionAveTime

(27)

Gauge

RO

Milliseconds

Execution time of the allocateConnection method of ConnectionManager (average value#2)

resourceAdapterCreateConnectionMaxTime

(28)

Gauge

RO

Milliseconds

Execution time of the createManagedConnection method of ManagedConnectionFactory (maximum value)

resourceAdapterCreateConnectionMinTime

(29)

Gauge

RO

Milliseconds

Execution time of the createManagedConnection method of ManagedConnectionFactory (minimum value)

resourceAdapterCreateConnectionAveTime

(30)

Gauge

RO

Milliseconds

Execution time of the createManagedConnection method of ManagedConnectionFactory (average value#2)

resourceAdapterGetConnectionFailedCount

(31)

Counter

RO

--

Number of failures of the allocateConnection method

resourceAdapterConnectionErrorCount

(32)

Counter

RO

--

Number of times a FATAL error occurred in ManagedConnection

Number of times the connectionErrorOccurred method of ConnectionEventListener was invoked

resourceAdapterStatisticsStartedTime

(33)

INTEGER

RO

Seconds

Statistics start time#3

resourceAdapterSamplingTime

(34)

INTEGER

RW

Seconds

Statistics sampling time#4

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

The output format is property-name=property-value:property-name=property-value:.... If the property name or property value includes an equal sign (=), colon (:), and a yen sign ([Figure]), these signs are displayed as \=, \:and \\.

(Example) abc=ab\:bc\=ef\\gh for property name ..."abc" and property value..."ab:bc=ef\gh"

#2

Average value of the past sampling time from the time of value acquisition request.

#3

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#4

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(23) statelessSessionBeanLocalHomeTable

The following table describes statelessSessionBeanLocalHomeTable:

Table A‒23: statelessSessionBeanLocalHomeTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

statelessSession

BeanLocalHomeTable

(23)

statelessSession

BeanLocalHomeEntry

(1)

statelessSessionBeanLocalHomeIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateless Session Bean Local Home Interface is used

statelessSessionBeanLocalHomeFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

statelessSessionBeanLocalHomeName

(3)

DisplayString

RO

--

LocalHome interface class name

statelessSessionBeanLocalHomeResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (maximum value)

statelessSessionBeanLocalHomeResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (minimum value)

statelessSessionBeanLocalHomeResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (average value#1)

statelessSessionBeanLocalHomeStatisticsStartedTime

(7)

INTEGER

RO

Seconds

Statistics start time#2

statelessSessionBeanLocalHomeSamplingTime

(8)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(24) statelessSessionBeanLocalComponentTable

The following table describes statelessSessionBeanLocalComponentTable:

Table A‒24: statelessSessionBeanLocalComponentTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

statelessSession

BeanLocalComponentTable

(24)

statelessSession

BeanLocalComponentTable

(1)

statelessSessionBeanLocalComponentIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateless Session Bean Local Component Interface is used

statelessSessionBeanLocalComponentFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

statelessSessionBeanLocalComponentFullyQualifiedName

(3)

DisplayString

RO

--

LocalComponent interface class name

statelessSessionBeanLocalComponentResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (maximum value)

statelessSessionBeanLocalComponentResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (minimum value)

statelessSessionBeanLocalComponentResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (average value#1)

statelessSessionBeanLocalComponentResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (maximum value)

statelessSessionBeanLocalComponentResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (minimum value)

statelessSessionBeanLocalComponentResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (average value#1)

statelessSessionBeanLocalComponentStatisticsStartedTime

(10)

INTEGER

RO

Seconds

Statistics start time#2

statelessSessionBeanLocalComponentSamplingTime

(11)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(25) statefulSessionBeanLocalHomeTable

The following table describes statefulSessionBeanLocalHomeTable:

Table A‒25: statefulSessionBeanLocalHomeTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

statefulSession

BeanLocalHomeTable

(25)

statefulSession

BeanLocalHomeEntry

(1)

statefulSessionBeanLocalHomeIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateful Session Bean Local Home Interface is used

statefulSessionBeanLocalHomeFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

statefulSessionBeanLocalHomeName

(3)

DisplayString

RO

--

LocalHome interface class name

statefulSessionBeanLocalHomeResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (maximum value)

statefulSessionBeanLocalHomeResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (minimum value)

statefulSessionBeanLocalHomeResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (average value#1)

statefulSessionBeanLocalHomeResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalHome interface (maximum value)

statefulSessionBeanLocalHomeResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalHome interface (minimum value)

statefulSessionBeanLocalHomeResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalHome interface (average value#1)

statefulSessionBeanLocalHomeStatisticsStartedTime

(10)

INTEGER

RO

Seconds

Statistics start time#2

statefulSessionBeanLocalHomeSamplingTime

(11)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(26) statefulSessionBeanLocalComponentTable

The following table describes statefulSessionBeanLocalComponentTable:

Table A‒26: statefulSessionBeanLocalComponentTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

statefulSession

BeanLocalComponentTable

(26)

statefulSession

BeanLocalComponentEntry

(1)

statefulSessionBeanLocalComponentIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateful Session Bean Local Component Interface is used

statefulSessionBeanLocalComponentFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

statefulSessionBeanLocalComponentName

(3)

DisplayString

RO

--

LocalComponent interface class name

statefulSessionBeanLocalComponentResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (maximum value)

statefulSessionBeanLocalComponentResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (minimum value)

statefulSessionBeanLocalComponentResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (average value#1)

statefulSessionBeanLocalComponentResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (maximum value)

statefulSessionBeanLocalComponentResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (minimum value)

statefulSessionBeanLocalComponentResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (average value#1)

statefulSessionBeanLocalComponentStatisticsStartedTime

(10)

INTEGER

RO

Seconds

Statistics start time#2

statefulSessionBeanLocalComponentSamplingTime

(11)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(27) entityBeanLocalHomeTable

The following table describes entityBeanLocalHomeTable:

Table A‒27: entityBeanLocalHomeTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

entityBeanLocalHomeTable

(27)

entityBeanLocalHomeEntry

(1)

entityBeanLocalHomeIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Entity Bean Local Home Interface is used

entityBeanLocalHomeFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

entityBeanLocalHomeName

(3)

DisplayString

RO

--

LocalHome interface class name

entityBeanLocalHomeResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (maximum value)

entityBeanLocalHomeResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (minimum value)

entityBeanLocalHomeResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (average value#1)

entityBeanLocalHomeResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalHome interface (maximum value)

entityBeanLocalHomeResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocaHome interface (minimum value)

entityBeanLocalHomeResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocaHome interface (average value#1)

entityBeanLocalHomeStatisticsStartedTime

(10)

INTEGER

RO

Seconds

Statistics start time#2

entityBeanLocalHomeSamplingTime

(11)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(28) entityBeanLocalComponentTable

The following table describes entityBeanLocalComponentTable:

Table A‒28: entityBeanLocalComponentTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

entityBeanLocal

ComponentTable

(28)

entityBeanLocal

ComponentEntry

(1)

entityBeanLocalComponentIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Entity Bean Local Component Interface is used

entityBeanLocalComponentFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

entityBeanLocalComponentName

(3)

DisplayString

RO

--

LocalComponent interface class name

entityBeanLocalComponentResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (maximum value)

entityBeanLocalComponentResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (minimum value)

entityBeanLocalComponentResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (average value#1)

entityBeanLocalComponentResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (maximum value)

entityBeanLocalComponentResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (minimum value)

entityBeanLocalComponentResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (average value#1)

entityBeanLocalComponentStatisticsStartedTime

(10)

INTEGER

RO

Seconds

Statistics start time#2

entityBeanLocalComponentSamplingTime

(11)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(29) messageDrivenBeanTable

The following table describes messageDrivenBeanTable:

Table A‒29: messageDrivenBeanTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

messageDrivenBeanTable

(29)

messageDrivenBeanEntry

(1)

messageDrivenBeanIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

A Message-driven Bean is used

messageDrivenBeanFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name"

messageDrivenBeanName

(3)

DisplayString

RO

--

Enterprise Bean name

messageDrivenBeanEjbClassName

(4)

DisplayString

RO

--

EJB class name

messageDrivenBeanTransactionType

(5)

DisplayString

RO

--

Transaction type

CMT or BMT

messageDrivenBeanDestinationType

(6)

DisplayString

RO

--

Destination types

Queue: Destination of the Point-To-Point model

Topic: Destination of the Publish-Subscribe model

messageDrivenBeanPoolUpperBound

(7)

INTEGER

RO

--

Number of instance pools (upper-limit value)

messageDrivenBeanCurrentPoolSize

(8)

Gauge

RO

--

Number of instance pools (current value)

messageDrivenBeanCurrentSessionCount

(9)

Gauge

RO

--

Number of connected sessions (current value)

messageDrivenBeanResponseEjbMaxTime

(10)

Gauge

RO

Milliseconds

Execution time of the EJB method (maximum value)

messageDrivenBeanResponseEjbMinTime

(11)

Gauge

RO

Milliseconds

Execution time of the EJB method (minimum value)

messageDrivenBeanResponseEjbAveTime

(12)

Gauge

RO

Milliseconds

Execution time of the EJB method (average value#1)

messageDrivenBeanStatisticsStartedTime

(10)

INTEGER

RO

Seconds

Statistics start time#2

messageDrivenBeanSamplingTime

(11)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(30) queueTable

The following table describes queueTable:

Table A‒30: queueTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

queueTable

(30)

queueEntry

(1)

queueIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

None

queueFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:queue-name"

queueName

(3)

DisplayString

RO

--

Queue name

queueStatus

(4)

DisplayString

RO

--

Status

scheduling:State in which scheduling is possible

preparing: Preparation in progress

stopping: Queue being terminated

closing[in]:Locking the queue entry

closing[out]: Locking the queue exit

queueSharedApplicationCount

(5)

INTEGER

RO

--

Number of applications sharing the queue

queueStayedRequestCount

(6)

Gauge

RO

--

Number of requests retained in the queue

queueStayedRequestMax

(7)

Gauge

RO

--

Maximum number of requests retained in the queue

queueLength

(8)

INTEGER

RO

--

Number of requests that can be registered concurrently

queueLookupName

(9)

DisplayString

RO

--

Registered name information managed by the queue

queueInterfaceName

(10)

DisplayString

RO

--

Interface information managed by the queue

queueParallelCount

(11)

INTEGER

RO

--

Number of concurrent executions managed by the queue

queueTotalThreadCount

(12)

INTEGER

RO

--

Total number of current resident threads managed by the queue

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

(31) statelessSessionBeanHomeMethodTable

The following table describes statelessSessionBeanHomeMethodTable:

Table A‒31: statelessSessionBeanHomeMethodTable

Table name (OID)

Entry name (OID)

Metric name (OID)

TYPE

R/W

Unit

Description

Preconditions

statelessSessionBean

HomeMethodTable

(31)

statelessSessionBean

HomeMethodEntry

(1)

statelessSessionBeanHomeMethodIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateless Session Bean Remote Home Interface Method is used

statelessSessionBeanHomeMethodFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name:Home-interface-class-name:method-name"

statelessSessionBeanHomeMethodName

(3)

DisplayString

RO

--

Method name

statelessSessionBeanHomeMethodResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the Home interface (maximum value)

statelessSessionBeanHomeMethodResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the Home interface (minimum value)

statelessSessionBeanHomeMethodResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the Home interface (average value#1)

statelessSessionBeanHomeMethodResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Home interface (maximum value)

statelessSessionBeanHomeMethodResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Home interface (minimum value)

statelessSessionBeanHomeMethodResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Home interface (average value#1)

statelessSessionBeanHomeMethodCallCount

(10)

Counter

RO

--

Number of executions of the method

statelessSessionBeanHomeMethodStatisticsStartedTime

(11)

INTEGER

RO

Seconds

Statistics start time#2

statelessSessionBeanHomeMethodSamplingTime

(12)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(32) statelessSessionBeanRemoteMethodTable

The following table describes statelessSessionBeanRemoteMethodTable:

Table A‒32: statelessSessionBeanRemoteMethodTable

Table name

(OID)

Entry name

(OID)

Metric name

(OID)

TYPE

R/W

Unit

Description

Preconditions

statelessSessionBean

RemoteMethodTable

(32)

statelessSessionBean

RemoteMethodEntry

(1)

statelessSessionBeanRemoteMethodIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateless Session Bean Remote Component Interface Method is used

statelessSessionBeanRemoteMethodFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name:Remote-interface-class-name:method-name"

statelessSessionBeanRemoteMethodName

(3)

DisplayString

RO

--

Method name

statelessSessionBeanRemoteMethodResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the Remote interface (maximum value)

statelessSessionBeanRemoteMethodResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the Remote interface (minimum value)

statelessSessionBeanRemoteMethodResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the Remote interface (average value#1)

statelessSessionBeanRemoteMethodResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Remote interface (maximum value)

statelessSessionBeanRemoteMethodResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Remote interface (minimum value)

statelessSessionBeanRemoteMethodResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Remote interface (average value#1)

statelessSessionBeanRemoteMethodCallCount

(10)

Counter

RO

--

Number of executions of the method

statelessSessionBeanRemoteMethodStatisticsStartedTime

(11)

INTEGER

RO

Seconds

Statistics start time#2

statelessSessionBeanRemoteMethodSamplingTime

(12)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(33) statelessSessionBeanLocalHomeMethodTable

The following table describes statelessSessionBeanLocalHomeMethodTable:

Table A‒33: statelessSessionBeanLocalHomeMethodTable

Table name

(OID)

Entry name

(OID)

Metric name

(OID)

TYPE

R/W

Unit

Description

Preconditions

statelessSessionBean

LocalHomeMethodTable

(33)

statelessSessionBean

LocalHomeMethodEntry

(1)

statelessSessionBeanLocalHomeMethodIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateless Session Bean Local Home Interface Method is used

statelessSessionBeanLocalHomeMethodFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name:LocalHome-interface-class-name:method-name"

statelessSessionBeanLocalHomeMethodName

(3)

DisplayString

RO

--

Method name

statelessSessionBeanLocalHomeMethodResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (maximum value)

statelessSessionBeanLocalHomeMethodResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (minimum value)

statelessSessionBeanLocalHomeMethodResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (average value#1)

statelessSessionBeanLocalHomeMethodResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalHome interface (maximum value)

statelessSessionBeanLocalHomeMethodResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalHome interface (minimum value)

statelessSessionBeanLocalHomeMethodResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalHome interface (average value#1)

statelessSessionBeanLocalHomeMethodCallCount

(10)

Counter

RO

--

Number of executions of the method

statelessSessionBeanLocalHomeMethodStatisticsStartedTime

(11)

INTEGER

RO

Seconds

Statistics start time#2

statelessSessionBeanLocalHomeMethodSamplingTime

(12)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(34) statelessSessionBeanLocalComponentMethodTable

The following table describes statelessSessionBeanLocalComponentMethodTable:

Table A‒34: statelessSessionBeanLocalComponentMethodTable

Table name

(OID)

Entry name

(OID)

Metric name

(OID)

TYPE

R/W

Unit

Description

Preconditions

statelessSessionBean

LocalComponentMethodTable

(34)

statelessSessionBean

LocalComponentMethodEntry

(1)

statelessSessionBeanLocalComponentMethodIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateless Session Bean Local Component Interface Method is used

statelessSessionBeanLocalComponentMethodFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name:LocalComponent-interface-class-name:method-name"

statelessSessionBeanLocalComponentMethodName

(3)

DisplayString

RO

--

Method name

statelessSessionBeanLocalComponentMethodResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (maximum value)

statelessSessionBeanLocalComponentMethodResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (minimum value)

statelessSessionBeanLocalComponentMethodResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (average value#1)

statelessSessionBeanLocalComponentMethodResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (maximum value)

statelessSessionBeanLocalComponentMethodResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (minimum value)

statelessSessionBeanLocalComponentMethodResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (average value#1)

statelessSessionBeanLocalComponentMethodCallCount

(10)

Counter

RO

--

Number of executions of the method

statelessSessionBeanLocalComponentMethodStatisticsStartedTime

(11)

INTEGER

RO

Seconds

Statistics start time#2

statelessSessionBeanLocalComponentMethodSamplingTime

(12)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(35) statefulSessionBeanHomeMethodTable

The following table describes statefulSessionBeanHomeMethodTable:

Table A‒35: statefulSessionBeanHomeMethodTable

Table name

(OID)

Entry name

(OID)

Metric name

(OID)

TYPE

R/W

Unit

Description

Preconditions

statefulSessionBean

HomeMethodTable

(35)

statefulSessionBean

HomeMethodEntry

(1)

statefulSessionBeanHomeMethodIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateful Session Bean Remote Home Interface Method is used

statefulSessionBeanHomeMethodFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name:Home-interface-class-name:method-name"

statefulSessionBeanHomeMethodName

(3)

DisplayString

RO

--

Method name

statefulSessionBeanHomeMethodResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the Home interface (maximum value)

statefulSessionBeanHomeMethodResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the Home interface (minimum value)

statefulSessionBeanHomeMethodResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the Home interface (average value#1)

statefulSessionBeanHomeMethodResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Home interface (maximum value)

statefulSessionBeanHomeMethodResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Home interface (minimum value)

statefulSessionBeanHomeMethodResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Home interface (average value#1)

statefulSessionBeanHomeMethodCallCount

(10)

Counter

RO

--

Number of executions of the method

statefulSessionBeanHomeMethodStatisticsStartedTime

(11)

INTEGER

RO

Seconds

Statistics start time#2

statefulSessionBeanHomeMethodSamplingTime

(12)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(36) statefulSessionBeanRemoteMethodTable

The following table describes statefulSessionBeanRemoteMethodTable:

Table A‒36: statefulSessionBeanRemoteMethodTable

Table name

(OID)

Entry name

(OID)

Metric name

(OID)

TYPE

R/W

Unit

Description

Preconditions

statefulSessionBean

RemoteMethodTable

(36)

statefulSessionBean

RemoteMethodEntry

(1)

statefulSessionBeanRemoteMethodIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateful Session Bean Remote Component Interface Method is used

statefulSessionBeanRemoteMethodFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name:Remote-interface-class-name:method-name"

statefulSessionBeanRemoteMethodName

(3)

DisplayString

RO

--

Method name

statefulSessionBeanRemoteMethodResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the Remote interface (maximum value)

statefulSessionBeanRemoteMethodResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the Remote interface (minimum value)

statefulSessionBeanRemoteMethodResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the Remote interface (average value#1)

statefulSessionBeanRemoteMethodResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Remote interface (maximum value)

statefulSessionBeanRemoteMethodResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Remote interface (minimum value)

statefulSessionBeanRemoteMethodResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the Remote interface (average value#1)

statefulSessionBeanRemoteMethodCallCount

(10)

Counter

RO

--

Number of executions of the method

statefulSessionBeanRemoteMethodStatisticsStartedTime

(11)

INTEGER

RO

Seconds

Statistics start time#2

statefulSessionBeanRemoteMethodSamplingTime

(12)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(37) statefulSessionBeanLocalHomeMethodTable

The following table describes statefulSessionBeanLocalHomeMethodTable:

Table A‒37: statefulSessionBeanLocalHomeMethodTable

Table name

(OID)

Entry name

(OID)

Metric name

(OID)

TYPE

R/W

Unit

Description

Preconditions

statefulSessionBean

LocalHomeMethodTable

(37)

statefulSessionBean

LocalHomeMethodEntry

(1)

statefulSessionBeanLocalHomeMethodIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateful Session Bean Local Home Interface Method is used

statefulSessionBeanLocalHomeMethodFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name:LocalHome-interface-class-name:method-name"

statefulSessionBeanLocalHomeMethodName

(3)

DisplayString

RO

--

Method name

statefulSessionBeanLocalHomeMethodResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (maximum value)

statefulSessionBeanLocalHomeMethodResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (minimum value)

statefulSessionBeanLocalHomeMethodResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the LocalHome interface (average value#1)

statefulSessionBeanLocalHomeMethodResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalHome interface (maximum value)

statefulSessionBeanLocalHomeMethodResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalHome interface (minimum value)

statefulSessionBeanLocalHomeMethodResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalHome interface (average value#1)

statefulSessionBeanLocalHomeMethodCallCount

(10)

Counter

RO

--

Number of executions of the method

statefulSessionBeanLocalHomeMethodStatisticsStartedTime

(11)

INTEGER

RO

Seconds

Statistics start time#2

statefulSessionBeanLocalHomeMethodSamplingTime

(12)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(38) statefulSessionBeanLocalComponentMethodTable

The following table describes statefulSessionBeanLocalComponentMethodTable:

Table A‒38: statefulSessionBeanLocalComponentMethodTable

Table name

(OID)

Entry name

(OID)

Metric name

(OID)

TYPE

R/W

Unit

Description

Preconditions

statefulSessionBean

LocalComponentMethodTable

(38)

statefulSessionBean

LocalComponentMethodEntry

(1)

statefulSessionBeanLocalComponentMethodIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

The Stateful Session Bean Local Component Interface Method is used

statefulSessionBeanLocalComponentMethodFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance

"logical-server-name:J2EE-application-name:EJB-application-name:Enterprise-Bean-name:LocalComponent-interface-class-name:method-name"

statefulSessionBeanLocalComponentMethodName

(3)

DisplayString

RO

--

Method name

statefulSessionBeanLocalComponentMethodResponseMaxTime

(4)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (maximum value)

statefulSessionBeanLocalComponentMethodResponseMinTime

(5)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (minimum value)

statefulSessionBeanLocalComponentMethodResponseAveTime

(6)

Gauge

RO

Milliseconds

Response time of calls to the LocalComponent interface (average value#1)

statefulSessionBeanLocalComponentMethodResponseEjbMaxTime

(7)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (maximum value)

statefulSessionBeanLocalComponentMethodResponseEjbMinTime

(8)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (minimum value)

statefulSessionBeanLocalComponentMethodResponseEjbAveTime

(9)

Gauge

RO

Milliseconds

Execution time of the EJB method for the LocalComponent interface (average value#1)

statefulSessionBeanLocalComponentMethodCallCount

(10)

Counter

RO

--

Number of executions of the method

statefulSessionBeanLocalComponentMethodStatisticsStartedTime

(11)

INTEGER

RO

Seconds

Statistics start time#2

statefulSessionBeanLocalComponentMethodSamplingTime

(12)

INTEGER

RW

Seconds

Statistics sampling time#3

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Average value of the past sampling time from the time of value acquisition request.

#2

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#3

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

(39) webContainerTable

The following table describes webContainerTable:

Table A‒39: webContainerTable

Table name

(OID)

Entry name

(OID)

Metric name

(OID)

TYPE

R/W

Unit

Description

Preconditions

webContainerTable

(39)

webContainerEntry

(1)

webContainerIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

None

webContainerFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance "logical-server-name"

webContainerServerName

(3)

DisplayString

RO

--

Server name of the Web container

webContainerStartedTime

(4)

INTEGER

RO

Seconds

Startup time of the Web container#1

webContainerStatisticsStartedTime

(5)

INTEGER

RO

Seconds

Statistics start time#1

webContainerSamplingTime

(6)

INTEGER

RW

Seconds

Statistics sampling time#2

webContainerActiveThreadCountUpperBound

(7)

INTEGER

RO

--

Upper-limit value of the number of active threads

  • A Web application (WAR) is used

  • The control functionality for concurrently executing threads is used

  • A Web application in which the number of concurrently executing threads is not set exists

webContainerCurrentThreadCountUpperBound

(8)

Gauge

RO

--

Current upper-limit value of the number of active threads#3

webContainerActiveThreadCount

(9)

Gauge

RO

--

Current number of active threads

webContainerActiveThreadCountHighWaterMark

(10)

Gauge

RO

--

Maximum number of active threads

webContainerActiveThreadCountLowWaterMark

(11)

Gauge

RO

--

Minimum number of active threads

webContainerActiveThreadCountAverage

(12)

Gauge

RO

--

Average value#4 of the number of active threads

webContainerActiveThreadCountPeak

(13)

Gauge

RO

--

Peak value#5of the number of active threads

webContainerWaitingRequestCountUpperBound

(14)

INTEGER

RO

--

Upper-limit value of the number of requests awaiting execution based on the upper-limit value set for the running threads

webContainerWaitingRequestCount

(15)

Gauge

RO

--

Current number of requests awaiting execution based on the upper-limit value set for the running threads

webContainerWaitingRequestCountHighWaterMark

(16)

Gauge

RO

--

Maximum number of requests awaiting execution based on the upper-limit value set for the running threads

webContainerWaitingRequestCountLowWaterMark

(17)

Gauge

RO

--

Minimum number of requests awaiting execution based on the upper-limit value set for the running threads

webContainerWaitingRequestCountAverage

(18)

Gauge

RO

--

Average value#4 of the number of requests awaiting execution based on the upper-limit value set for the running threads

webContainerWaitingRequestCountPeak

(19)

Gauge

RO

--

Peak value#5 of the number of requests awaiting execution based on the upper-limit value set for the running threads

webContainerOverflowRequestCount

(20)

Counter

RO

--

Total number of requests in which an error is returned based on the upper limit value that is set up for the default pending request

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only

RW: Read-Write

#1

Number of seconds elapsed since 00:00 Jan. 1, 1970 UTC

#2

Setting the sampling time

If you specify 0 or a lesser value, the statistics stops. If you specify a value from 1 to 9, the sampling time is set to the default value (10 seconds) and the statistics starts. If you specify 10 or a higher value, the statistics starts assuming the specified value as the sampling time.

#3

Upper-limit value for the number of threads that can be concurrently executed at present

#4

Average value of the past sampling time from the time of value acquisition request.

#5

Peak value at the point of value acquisition request (the maximum value involving the available period of the sampling time after recording).

(40) queueAppTable

The following table describes queueAppTable:

Table A‒40: queueAppTable

Table name

(OID)

Entry name

(OID)

Metric name

(OID)

TYPE

R/W

Unit

Description

Preconditions

queueAppTable

(40)

queueAppEntry

(1)

queueAppIndex

(1)

INTEGER

RO

--

Sequence number [1,...]

None

queueAppFullyQualifiedName

(2)

DisplayString

RO

--

Fully qualified name that uniquely identifies an instance "logical-CTM-server-name:queue-name:logical-J2EE-server-name"

queueAppQueueName

(3)

DisplayString

RO

--

Queue name

queueAppJ2EEName

(4)

DisplayString

RO

--

Actual J2EE server name

queueAppStartParallelCount

(5)

INTEGER

RO

--

Number of concurrent executions when the J2EE application is started

queueAppResidentThreadCount

(6)

INTEGER

RO

--

Number of current resident threads for the J2EE application

Legend:

R/W:Read-Only/ Read-Write type

--: Not applicable

RO: Read-Only