Hitachi

uCosminexus Application Server Definition Reference Guide


8.3.3 manager.Logical-server-name.jp1event.system.mapping.properties (Message mapping file for individual J2EE servers)

Organization of this subsection

(1) Format

J2SE property file format.

mserver.jp1event.system.mapping.severity.Message-ID = Criticality-of-JP1-event
Message-ID

Specifies the message ID described in the following manual:

  • Manual uCosminexus Application Server Messages

Criticality-of-JP1-event

Specify any one of the values from Information, Notice, Warning, Error, Critical, Alert, or Emergency.

(2) File storage location

(3) Functionality

You create this file when you want to define the mapping rules for each J2EE server. When this file is defined, Cosminexus uses only the individual file for the corresponding J2EE server and converts the log messages output by the J2EE server into JP1 events.

(4) Examples of coding

manager.jp1event.system.mapping.severity.KDJE42020-E=Error
manager.jp1event.system.mapping.severity.KDJE42041-I=Information