KDSF0052-W
Polling to xxxxxxxx (yyyyyyyy) from hhhhhhhh (iii.iii.iii.iii, dddddddd) failed. ID key for operations=0xnn, {Win32|Socket|Runtime|Protocol} error, Code=mm[: nnnnnn][, zzzzzzzz]
- Cause
-
Polling failed due to an error. (The error might be a temporary error.)
xxxxxxxx: Host name or IP address of the polling-destination device.
When connecting via Internet Gateway, use local hostname.
- yyyyyyyy: Product type of the polling-destination device
-
netmdm: Manager
netmdmw: Relay system
netmgw: Connecting via Internet Gateway
hhhhhhhh: Local host name
iii.iii.iii.iii: IP address of the local host
dddddddd: Host ID of the local host
- 0xnn: Operation key for the higher-level system
-
0x03: Host name
0x04: IP address
0xff: The operation key information is invalid.
- {Win32|Socket|Runtime|Protocol}: Type of error
-
Win32: Win32 API error
Socket: Socket error
Runtime: C runtime error
Protocol: Protocol error
mm: Error code
nnnnnn: Explanation of the error code indicated by mm
zzzzzzzz: Maintenance information
- Action
-
Check whether the host name (or IP address) and the product type of the polling-destination device are correct. If these settings are correct, make sure that the higher-level system of the polling-destination device is running.