Hitachi

JP1 Version 12 JP1/IT Desktop Management 2 Overview and System Design Guide


4.3.5 Prerequisites for acquiring operation logs

To acquire operation logs, the agent must be installed on the computer from which you want to acquire operation logs.

Prerequisites for acquiring an operation log vary depending on the log type, as described in the following table.

Operation log type

Prerequisites

Computer operation

Start and stop of the computer

--

Logon to and logoff from the OS

Start and termination of the programs

The combined length of the file name and folder name for logged programs must be less than 260 characters.

File and folder operation

File and folder operation in the computer

--

Upload to and download from the Web

Operation logs for the following Web browsers can be acquired:

  • Internet Explorer 9, 10, 11#1

  • If your Web browser is Internet Explorer 10 or 11, the Enable third-party browser extensions check box must be selected on the Advanced Settings tab in the Internet Options dialog box. Note that this check box is cleared by default for Internet Explorer installed in Windows Server 2012 and Windows Server 2008 R2.

  • If your Web browser is Internet Explorer 10 or 11, the JP1/IT Desktop Management 2 FUO add-on must be enabled in the list of add-ons displayed by selecting Tools, Manage Add-ons, and then Toolbars and Extensions.

E-mail transmission and reception

Operation logs for the following e-mail clients can be acquired:

  • Microsoft Outlook 2002, 2003, 2007, 2010, 2013, 2016, and 2019

  • Windows Live Mail 2009, 2011, and 2012

Save of attached files

File transmission and reception

Operation logs for the following Web browsers can be acquired:

  • Internet Explorer 9, 10, and 11#1

Print operation

In the properties for each printer, Print and Manage Documents must be allowed for all logged on users.#2

Web access

  • Operation logs for the following Web browsers can be acquired:

    • Internet Explorer 9, 10, and 11#1

  • The Enable third-party browser extensions check box must be selected on the Advanced Settings tab in the Internet Options dialog box. Note that this check box is cleared by default for Internet Explorer installed in Windows Server 2012 and Windows Server 2008 R2.

  • The add-on for Web access monitoring that is added to the user's computer must be enabled.

  • In addition, JP1/IT Desktop Management 2 BHO must be enabled in the list of add-ons displayed by selecting Tools, Manage Add-ons, and then Toolbars and Extensions.

Connection and disconnection of devices

--

Window operation

--

Legend: --: None

#1: Operation logs for Web upload, Wed download, file reception, and Web access can be acquired only for desktop Internet Explorer for which Enhanced Protected Mode is disabled.

#2: For the network shared printer, the following prerequisites are added.

Important

Agents for UNIX and Mac are excluded from operation log collection.