User defined Monitor (Perf.) (PI_UMP)
- Organization of this page
Function
In SAP system monitor information, the User defined Monitor (Perf.) (PI_UMP) record stores performance data collected according to user definitions. One record is created for each MTE whose MTE type is the performance attribute in the specified SAP system monitor information.
Default and changeable values
Item |
Default value |
Changeable |
---|---|---|
Collection Interval |
600 |
Y |
Collection Offset |
45 |
Y |
Log |
No |
Y |
LOGIF |
(Blank) |
Y |
Over 10 Sec Collection Time |
No |
N |
Realtime Report Data Collection Mode |
Reschedule |
Y |
ODBC key fields
PI_UMP_MTE_NAME
Lifetime
None
Record size
-
Fixed part: 833 bytes
-
Variable part: 293 bytes
Fields
PFM - View name (PFM - Manager name) |
Description |
Smry |
Frmt |
Delta |
Sup. ver. |
Data source |
---|---|---|---|---|---|---|
Instance Name (INSTANCE_NAME) |
SAP instance name. This name usually consists of a host name, SAP system ID, and system number. This setting can be changed by the rdisp/myname parameter. |
COPY |
string(21) |
No |
7.00 or later |
-- |
Interval (INTERVAL) |
Interval in seconds at which records were stored (current value in Record Time field - previous value in Record Time field). The initial value is 0. |
ADD |
ulong |
No |
7.00 or later |
-- |
Measured Date (MEASURED_DATE) |
Measured date for the performance value (Measured Value) |
COPY |
String(9) |
No |
7.00 or later |
RZ20 |
Measured Time (MEASURED_TIME) |
Measured time for the performance value (Measured Value) |
COPY |
String(7) |
No |
7.00 or later |
RZ20 |
Measured Value (MEASURED_VALUE) |
Performance value (already obtained in the SAP system) |
HILO |
float |
No |
7.00 or later |
RZ20 |
Monitor Name (MONITOR_NAME) |
Monitor name |
COPY |
string(61) |
No |
7.00 or later |
RZ20 |
Monitor Set (MONITOR_SET) |
Monitor set name |
COPY |
string(61) |
No |
7.00 or later |
RZ20 |
MTE Context (MTE_CONTEXT) |
Name of Context part of MTE |
COPY |
string(41) |
No |
7.00 or later |
RZ20 |
MTE Name (MTE_NAME) |
MTE name (MTE's System ID part, Context part, Objectname part, and Shortname part connected by a backslash (\); for example, SAP-system-ID\SAP-instance-name\Background\Utilisation) |
COPY |
string(132) |
No |
7.00 or later |
RZ20 |
MTE Objectname (MTE_OBJECTNAME) |
Name of Objectname part of MTE |
COPY |
string(41) |
No |
7.00 or later |
RZ20 |
MTE Shortname (MTE_SHORTNAME) |
Name of Shortname part of MTE |
COPY |
string(41) |
No |
7.00 or later |
RZ20 |
MTE System ID (MTE_SYSTEM_ID) |
Name of System ID part of MTE |
COPY |
string(9) |
No |
7.00 or later |
RZ20 |
Record Time (RECORD_TIME) |
Record creation time |
COPY |
time_t |
No |
7.00 or later |
-- |
Record Type (INPUT_RECORD_TYPE) |
Record type (UMP) |
COPY |
char(8) |
No |
7.00 or later |
-- |
System ID (SYSTEM_ID) |
SAP system ID |
COPY |
string(9) |
No |
7.00 or later |
-- |
Unit (UNIT) |
Unit for performance value |
COPY |
string(5) |
No |
7.00 or later |
RZ20 |
Value (VALUE) |
Performance value |
HILO |
float |
No |
7.00 or later |
RZ20 |
- Legend:
-
Smry: Summary
Frmt: Format
Sup. ver.: Supported version