Hitachi

JP1 Version 12 JP1/Performance Management - Agent Option for Enterprise Applications Description, User's Guide and Reference


System Log Monitor Command (PD_SLMX)

Organization of this page

Function

The System Log Monitor Command (PD_SLMX) record stores the result of extracting the system log information of the SAP system. One record is created for each SAP instance.

Note
  • This record cannot be displayed in real-time reports.

Default and changeable values

Item

Default value

Changeable

Collection Interval

600

Y

Collection Offset

0

Y

Log

No

Y

LOGIF

(Blank)

Y

Over 10 Sec Collection Time

No

N

Realtime Report Data Collection Mode

Reschedule

Y

ODBC key fields

None

Lifetime

None

Record size

Fields

PFM - View name

(PFM - Manager name)

Description

Frmt

Delta

Sup. ver.

Data source

Elapsed Time

(ELAPSED_TIME)

Command execution time in milliseconds

ulong

No

7.00 or later

--

Exit Code

(EXIT_CODE)

Command termination code

ulong

No

7.00 or later

--

Instance Name

(INSTANCE_NAME)

SAP instance name. This name usually consists of a host name, SAP system ID, and system number. This setting can be changed by the rdisp/myname parameter.

string(21)

No

--

--

Interval

(INTERVAL)

Interval in seconds at which records were stored (current value in Record Time field - previous value in Record Time field). The initial value is 0.

ulong

No

--

--

Path

(PATH)

Command path (excluding the argument part)

string(256)

No

7.00 or later

--

Record Time

(RECORD_TIME)

Record creation time

time_t

No

--

--

Record Type

(INPUT_RECORD_TYPE)

Record type (SLMX)

char(8)

No

--

--

Stderr Buffer

(STDERR_BUFFER)

Standard error output buffer for the command

string(2049)

No

7.00 or later

--

Stdout Buffer

(STDOUT_BUFFER)

Standard output buffer for the command

string(2049)

No

7.00 or later

--

System ID

(SYSTEM_ID)

SAP system ID

string(9)

No

--

--

Legend: