Hitachi

JP1 Version 12 for UNIX Systems JP1/Performance Management - Agent Option for Platform Description, User's Guide and Reference


User Data Interval - Expanded 5 (PI_XUI5)

Organization of this page

Function

User Data Interval - Expanded 5 (PI_XUI5) record is a user-defined record that stores user-specific performance data per unit time. This record has more fields than the User Data Interval - Extended (PI_UPIB) record.

Default values and values that can be specified

Item

Default value

Modifiable

Collection Interval

60

Yes

Collection Offset#

0

Yes

Log

No

Yes

LOGIF

Blank

Yes

Over 10 Sec Collection Time

Yes

No

Realtime Report Data Collection Mode

Reschedule

Yes

#

You can specify a value in the range from 0 to 32,767 seconds (which must not exceed the range specified by Collection Interval). This item is used to distribute the processing load resulting from the collection of multiple data items at a time. Note that the recorded data collection duration is the same as the value set for Collection Interval, regardless of the value set for Collection Offset.

When changing the Collection Offset value, specify a value that takes into account the impact of the collection processing load.

ODBC key fields

Lifetime

From the execution of the jpcuser command until the execution of the next jpcuser command

Record size

Fields

The value in the Record Type field is XUI5. The value in other fields is the same as that stored in the PI_XUI1 record.