Hitachi

JP1 Version 12 for UNIX Systems JP1/Performance Management - Agent Option for Platform Description, User's Guide and Reference


7.2.2 Differences in functionality from previous versions

The following table shows the differences in functionality between how past versions collected information about the application operating status and how version 10-00 collects information about the operating status of processes.

Table 7‒1: Differences from previous versions in the collection of information about the operating status of processes

Functionality

Collection of information about the application operating status in versions 09-00 and earlier

Collection of information about the operating status of processes beginning with version 10-00

Acquisition of command line

Yes

Yes

Maximum value for a command line that can be acquired

119 bytes

4,096 bytes

Collection of performance information for specific processes

No#1

Yes#2

Maximum value for monitoring conditions that can be specified

127 bytes

4,096 bytes

Maximum value for monitoring conditions that can be displayed in PFM - Web Console

31 bytes

4,096 bytes

Case sensitivity of monitoring targets

No

Yes#3

Identifying monitoring conditions by label

No

Yes#4

Grouping targets when setting process monitoring

  • Programs (Name)

  • Services (Argument List)

  • Programs (Program Name)

  • Command line (Command Line)

Legend:

Yes: Can be executed.

No: Cannot be executed.

#1

Always collects performance information for all processes.

#2

Collects performance information only for the processes for which process monitoring has been set.

#3

By default, letter case is distinguished. For details, see 7.2.7 Distinguishing the letter case of monitoring targets.

#4

Use the MonitoringXX Label field to identify a process.

You can use the jpcappcvt command to upgrade application definitions that were set in version 09-00 or earlier to application definitions for version 10-00. For details about the jpcappcvt command, see 10. Commands.

Note

There is no need to upgrade application definitions that were set in version 09-00 or earlier if they are not being extended into version 10-00.