Hitachi

JP1 Version 12 for Windows Systems JP1/Performance Management - Agent Option for Platform Description, User's Guide and Reference


Event Log (all)

Organization of this page

Overview

The Event Log (all) alarm monitors all errors and warnings output to the event log. Note that you can use the collection data addition utility to specify the event logs as the target for data collection. For details about the settings required for using the collection data addition utility to collect event log data, see 6.3 Settings for collecting event log information.

Note

This alarm terminates alarm evaluation when at least one abnormal or warning value is detected. Accordingly, not all collected data is evaluated. Because each log in the event log has specific information that is not related to previous evaluation, we recommend that all collected data be evaluated.

To evaluate all data, copy this alarm and create an alarm with Enable alarm, Always notify, and Evaluate all data selected in the PFM - Web Console alarm properties. Then use this alarm to perform monitoring.

Primary settings

PFM - Web Console alarm property

Settings

Item

Detailed item

Main Information

Product

Windows

Alarm message

%CVS1 %CVS2, %CVS3 (%CVS4), %CVS5

Enable alarm

Selected

Alarm notification

Notify when the state changed

Notification target

State changes for the alarm

Evaluate all data

Do not specify.

Monitoring time range

Always monitor

Report alarm when the following damping condition is reached.

Selected

occurrence(s) during

1

interval(s)

1

Alarm Conditions 1

Record

Event Log (PD_ELOG)

Field

Log Name

Abnormal condition

Log Name <> dummy#1

Warning condition

Log Name <> dummy#1

Alarm Conditions 2

Record

Event Log (PD_ELOG)

Field

Event Type Name

Abnormal condition

Event Type Name = Error

Warning condition

Event Type Name = Warning

Alarm Conditions 3

Record

Event Log (PD_ELOG)

Field

Source Name

Abnormal condition

Source Name <> dummy#2

Warning condition

Source Name <> dummy#2

Alarm Conditions 4

Record

Event Log (PD_ELOG)

Field

Event ID

Abnormal condition

Event ID <> 0

Warning condition

Event ID <> 0

Alarm Conditions 5

Record

Event Log (PD_ELOG)

Field

Description

Abnormal condition

Description <> dummy#3

Warning condition

Description <> dummy#3

Actions

Email

--

Command

--

SNMP

Abnormal, Warning, Normal

Legend:

--: Setting is always invalid.

#1

Set the type of event log to be monitored. The value used in the table shows an example of setting a condition value satisfies the Log Name field.

#2

Set the name of the source for which entries were generated. The value used in the table shows an example of setting a condition value that satisfies the Source Name field.

#3

Set the description of the event log. The value used in the table shows an example of setting a condition value that satisfies the Description field.

Alarm table

PFM Windows Template Alarms [LOG] 09.00

Related reports

None