Process Alive
- Organization of this page
Overview
The Process Alive alarm monitors the generation of processes that belong to a workgroup.
Use the collection data addition utility to specify monitoring of processes as follows.
Items in the collection data addition utility#1 |
Description#3 |
---|---|
Match all program name, user name, and group name conditions (AND) |
Selected |
Workgroup name |
workgroup |
Program name#2 |
yyy|zzz |
User name |
-- |
Group name |
-- |
- Legend:
-
--: Not specified.
- #1
-
Execute the collection data addition utility in an environment in which PFM - Agent for Platform has been installed. For details about how to specify the settings for collecting workgroup information, see 6.4 Settings for collecting workgroup information.
- #2
-
For the program name, specify either of the following:
- An instance of the Process object displayed from System Monitor by choosing Administrative Tools from the Windows Start menu and then Performance and System Monitor
- Value of the Program field of the PD record.
- #3
-
In this example, processes named yyy and zzz are set in a workgroup.
Primary settings
PFM - Web Console alarm property |
Settings |
|
---|---|---|
Item |
Detailed item |
|
Main Information |
Product |
Windows |
Alarm message |
Workgroup Application Process Count = %CVS1 |
|
Enable alarm |
Selected |
|
Alarm notification |
Notify when the state changed |
|
Notification target |
State changes for the alarm |
|
Evaluate all data |
Do not specify. |
|
Monitoring time range |
Always monitor |
|
Report alarm when the following damping condition is reached. |
Do not specify. |
|
occurrence(s) during |
0 |
|
interval(s) |
0 |
|
Alarm Conditions 1 |
Record |
Workgroup Summary (PI_WGRP) |
Field |
Process Count |
|
Abnormal condition |
Process Count > 0 |
|
Warning condition |
Process Count > 0 |
|
Alarm Conditions 2 |
Record |
Workgroup Summary (PI_WGRP) |
Field |
Workgroup |
|
Abnormal condition |
Workgroup = workgroup# |
|
Warning condition |
Workgroup = workgroup# |
|
Actions |
|
-- |
Command |
-- |
|
SNMP |
Abnormal, Warning, Normal |
- Legend:
-
--: Setting is always invalid.
- #
-
Set the name of the workgroup to be monitored. This name must be set in the collection data addition utility.
Alarm table
PFM Windows Template Alarms [PS] 10.00
Related reports