Hitachi

JP1 Version 12 JP1/Performance Management - Remote Monitor for Oracle Description, User's Guide and Reference


Parameter Values (PD_PDP)

Organization of this page

Function

The Parameter Values (PD_PDP) record stores performance data indicating the status (at a specific point in time) of current parameter values. PFM - RM for Oracle creates one record for each parameter. This is a multi-instance record.

Default and changeable values

Item

Default value

Changeable

Collection Interval

600

Y

Collection Offset

85

Y

Log

No

Y

LOGIF

(Blank)

Y

Over 10 Sec Collection Time

No

N

ODBC key fields

PD_PDP_NAME

Lifetime

From the creation to the deletion of an Oracle instance

Record size

Fields

PFM - View name

(PFM - Manager name)

Description

Summary

Format

Delta

Supported version

Data source

Is Default

(IS_DEFAULT)

Whether or not the value is the default. Valid values are TRUE and FALSE.

--

string(9)

No

All

V$PARAMETER.ISDEFAULT

Parameter Name

(NAME)

Parameter name

--

string(64)

No

All

V$PARAMETER.NAME

Record Time

(RECORD_TIME)

Collection termination time for the performance data stored in the record

--

time_t

No

All

Remote Monitor Collector

Record Type

(INPUT_RECORD_TYPE)

Record name (always PDP)

--

string(4)

No

All

Remote Monitor Collector

Start Time

(START_TIME)

Collection start time for the performance data stored in the record

--

time_t

No

All

Remote Monitor Collector

VA DeviceID

(VADEVICEID)

Device ID of virtual agent.

--

string(256)

No

All

Remote Monitor Collector

Value

(VALUE)

Parameter value

--

string(512)

No

All

V$PARAMETER.VALUE