Overview

The Full Table Scans alarm monitors the percentage of full table scans.

Main settings

Alarm properties in PFM - Web Console

Setting

Item

Detailed item

Main Information

Product

RM Oracle(8.0)

Alarm message

Non-index lookups %CVS%

Enable alarm

Selected

Alarm notification

Notify when the state changed

Notification target

State changes for the alarm

Evaluate all data

Not selected

Monitoring time range

Always

Report alarm when the following damping condition is reached

Not selected

occurrence(s) during

--

interval(s)

--

Alarm Conditions

Record

System Stat Summary Interval (PI)

Field

Non-Index Lookups %

Abnormal condition

Non-Index Lookups % > 10

Warning condition

Non-Index Lookups % > 5

Actions

E-mail

--

Command

--

SNMP

Abnormal, Warning, Normal

Legend:

--: The setting is always invalid.

Related reports