Hitachi

JP1 Version 12 JP1/Performance Management - Remote Monitor for Platform Description, User's Guide and Reference


Target Host Status (historical report indicating the status of the connection to the monitored host and information about the OS of the monitored host)

Organization of this page

Overview

The Target Host Status report displays the minute-by-minute status of the connection to the monitored host and information about the OS of the monitored host over the past hour.

Storage location

/RM Platform/Troubleshooting/Recent Past

Record

PD

Fields

Table 6‒72: Description of fields (Target Host Status (historical report indicating the status of the connection to the monitored host and information about the OS of the monitored host))

Field name

Description

Detail

Detailed information about the monitored host

OS Type

Name of the OS of the monitored host

Polling Time

Time the performance data was collected on the PFM - RM host

Processor Type

Processor type of the monitored host

Reason

Cause of ERROR in the Status field. If the value of Status field is SUCCESS, this field contains a null character string.

When Connection failed is displayed:

Connection failed.

When Authorization failed is displayed:

Authentication failed.

When Response invalid is displayed:

An unexpected response was received from the server.

When Collection error is displayed:

A collection error occurred.

When Collection timeout is displayed:

A collection timeout occurred.

When Invalid environment(SSH_Client) is displayed:

The file specified in SSH_Client when the instance environment was set up does not exist (when the PFM - RM host is running Windows and the monitored host is running UNIX).

When Invalid environment(Perl_Module) is displayed:

The file specified in Perl_Module when the instance environment was set up does not exist (when the PFM - RM host is running Windows and the monitored host is running UNIX).

When Invalid environment(Private_Key_File) is displayed:

The file specified in Private_Key_File when the monitored host was set up does not exist (when the PFM - RM host is running Windows and the monitored host is running UNIX).

Status

Connection status.

When SUCCESS is displayed:

Execution is underway.

When ERROR is displayed:

Connection failed.

Target Host Time

Time the performance data was collected on the monitored host

Version