Process Existence
- Organization of this page
Overview
The Process Existence alarm monitors the existence of processes. If the existence of a process cannot be confirmed, it means that the process has stopped.
Main settings
Alarm properties in PFM - Web Console |
Setting |
|
---|---|---|
Item |
Details |
|
Main Information |
Product |
RM Platform |
Alarm message |
Process status has changed |
|
Enable alarm |
Selected |
|
Alarm notification |
Notify when the state changed |
|
Notification target |
State changes for the alarm |
|
Evaluate all data |
Do not specify. |
|
Monitoring time range |
Always monitor |
|
Report alarm when the following damping condition is reached |
Do not specify. |
|
occurrence(s) during |
0 |
|
interval(s) |
0 |
|
Alarm Conditions |
Record |
Application Process Overview (PD_APS) |
Field |
Program Name |
|
Abnormal condition |
Program Name = jpcsto.exe# |
|
Warning condition |
Program Name = jpcsto.exe# |
|
Actions |
|
-- |
Command |
-- |
|
SNMP |
Abnormal, Normal |
- Legend:
-
--: The setting is always ignored.
- #
-
Specify the name of the program to be monitored. Make sure that the character string you enter matches what is entered in the Program Name field of the PD_APS record.
Any character in the information to be acquired that is not in the ASCII character set range of 0x20 to 0x7E will be converted to a hash mark (#: 0x23) before it is stored in the Program Name field of the PD_APS record. Note that multi-byte characters are processed in single-byte units during conversion. For example, the multi-byte (full-width) letter
is converted as follows:
Information to be acquired
Information after conversion
Character encoding
Binary
Binary
Character string
Shift-JIS
8260
2360
#`
EUC
A3C1
2323
##
UTF-8
EFBCA1
232323
###
Alarm table
PFM RM Platform Template Alarms [PS] 09.10
Related reports
None.