Hitachi

JP1 Version 12 JP1/Performance Management - Remote Monitor for Platform Description, User's Guide and Reference


Application Status

Organization of this page

Overview

The Application Status alarm monitors the status of the application being monitored by the Application Summary (PD_APP2) record.

Main settings

Table 6‒3: PFM - Web Console alarm property setting (Application Status)

Alarm properties in PFM - Web Console

Setting

Item

Details

Main Information

Product

RM Platform

Alarm message

Status of application(%CVS1) has changed

Enable alarm

Selected

Alarm notification

Notify when the state changed

Notification target

State changes for the alarm

Evaluate all data

Selected

Monitoring time range

Always monitor

Report alarm when the following damping condition is reached

Do not specify.

occurrence(s) during

0

interval(s)

0

Alarm Conditions

Record

Application Summary (APP2)

Field

  • Application Name

  • Application Exist

  • Application Status

Abnormal condition

Application Name = *

AND Application Exist = ABNORMAL

AND Application Status = ABNORMAL

Warning condition

Application Name = *

AND Application Exist = NORMAL

AND Application Status = ABNORMAL

Actions

Email

--

Command

--

SNMP

Abnormal, Warning, Normal

Legend:

--: The setting is always ignored.

Alarm table

PFM RM Platform Template Alarms [APP] 09.10

Related reports

Reports/RM Platform/Troubleshooting/Real-Time/Application Status