Hitachi

JP1 Version 12 JP1/Performance Management Reference


jpctool config alarmsync

Organization of this page

Format

jpctool config alarmsync     [-noprogress]
                             [-target alarm-application-status]

Function

This command applies alarm information to services whose alarm application status is Failed (failed to be applied) or Uncertain (status unknown). You can also target execution to only those services whose status is Failed (failed to be applied) or to only those services whose status is Uncertain (status unknown). After executing the jpctool config alarmsync command, execute the jpctool alarm unapplied command to verify whether the alarm information was properly applied.

Hosts that can execute the command

PFM - Manager

Execution permission

In Windows:

User with Administrators permissions

In UNIX:

User with root user permissions

Installation directory

In Windows:

installation-folder\tools\

In UNIX:

/opt/jp1pc/tools/

Arguments

-noprogress

If this option is specified, the progress of the application processing is not output.

-target alarm-application-status

Specify this option if you want to target execution to only services whose status is Failed (failed to be applied) or only services whose status is Uncertain (status unknown). Specify the alarm application status to be targeted in alarm-application-status.

Notes

Return values

0

The command terminated normally.

1

The command line format is invalid.

2

The user does not have execution permission for the command.

5

The command was executed on a host that was not the PFM - Manager host.

12

The command jpctool config sync or jpctool config alarmsync is currently executing.

17

This command was executed from the secondary PFM - Manager in a multiple-monitoring environment.

101

The Master Manager service is not running.

200

A memory shortage occurred.

211

A file or directory cannot be accessed.

221

An attempt to acquire information on the alarm application status from the Master Manager service failed.

222

An error occurred during communication processing.

237

A timeout occurred while determining the results of applying the alarm information.

255

An unexpected error occurred.

Usage example

>jpctool config alarmsync
KAVE06201-I Application processing of the alarm definition and action definition will now start.
[50/50]
KAVE06205-I Processing of the application results judgment will now start.
KAVE06206-I Processing of the application results judgment ended normally.
KAVE06202-I Application processing of the alarm definition and action definition ended normally.