17.3.1 When the jpctool config mgrimport command is executed, an error is output

If the KAVE06142-E message is output to the standard error output and common message log, the import has failed because duplicated definition information is inconsistent. In that case, do the following in PFM - Manager on the secondary Manager.

  1. Check the definition information name shown in KAVE06142-E.

  2. Reference the description of how to verify definition information in the manual JP1/Performance Management Reference. Determine the definition information (file name, section name/label name, or property name) which is inconsistent from the definition information name.

  3. After you have determined the inconsistent definition information, change the corresponding definition information on the secondary Manager so that it matches with that on the primary Manager and then perform an import.

    After you change definition information on the primary Manager, you must export the definition information from the primary Manager, copy it to the secondary Manager, and then import it. For details, see 11.5.1 Procedure for duplicating definition information.