Hitachi

JP1 Version 12 JP1/Performance Management User's Guide


11.3.6 Setting operation monitoring

You must set the following items before you can duplicate definition information. Set the following information on both the primary Manager host and the secondary Manager host.

Set anything required for operation monitoring at the same time.

Organization of this subsection

(1) Additional settings to be specified when you are using the auto alarm bind function

When you are using the auto alarm bind function, specify the following settings:

(a) Enabling the products

On the PFM - Manager host, execute the following command to confirm if the pre-registration of alarms or reports is enabled for the agents to which you want to apply the auto alarm bind function:

jpcconf agent list

If the pre-registration of alarms or reports is not enabled for the agents, enable it by executing the following command:

jpcconf agent setup -key service-key -register
Note

If you execute the command with the service key of agents specified by mistake, you can use the following command to restore the setting back to its previous state:

jpcconf agent setup -key service-key -unregister

(b) Specifying the auto alarm bind setting

You can specify the auto alarm bind setting as follows:

When using PFM - Web Console

Specify the auto alarm bind setting from the Automatic Bind Settings window. For details, see the section describing the Auto Alarm Bind Setting window in the manual JP1/Performance Management Reference.

When using PFM - Manager

Directly edit the auto alarm bind setting file. For details, see the section describing the auto alarm bind setting file (jpcautobind.cfg) in the manual JP1/Performance Management Reference.

Important
  • With PFM -Web Console, you only need to specify the auto alarm bind setting on the primary manager (no need to specify the same setting on the secondary manager).

  • If you change the auto alarm bind setting after configuring a multiple monitoring environment, you have to duplicate definition information again to ensure synchronization. For details, see 11.5 Duplicating definition information. For details about how to confirm synchronization, see 11.6.1(8) Checking the settings of auto alarm bind.