9.2.11 Backing up and restoring specific definition information (auto alarm bind definition information)

This subsection describes how to manually back up and restore auto alarm bind definition information (specifically, the auto alarm bind setting file).

By default, the auto alarm bind setting file is placed in the following location on the PFM - Manager host:

Organization of this subsection

(1) Backing up auto alarm bind definition information

You can manually back up only the auto alarm bind setting file by following the procedure described below. This procedure assumes that the file is stored in the default location.

  1. Stop the PFM - Manager services.

    For details about how to stop the services, see 1.3.1 Stopping services on monitoring managers and monitoring agents.

  2. Back up the jpcautobind.cfg file located under the auto alarm bind setting file storage directory.

    Back up the file by copying it to any location you like or using a similar manner.

  3. Start the PFM - Manager services.

    For details about how to start the services, see 1.2.1 Starting services on monitoring managers and monitoring agents.

(2) Restoring auto alarm bind definition information

You can manually restore only the auto alarm bind setting file by following the procedure described below. This procedure assumes that the file is stored in the default location.

  1. Stop the PFM - Manager services.

    For details about how to stop the services, see 1.3.1 Stopping services on monitoring managers and monitoring agents.

  2. Copy the backed-up jpcautobind.cfg file to the auto alarm bind setting file storage directory.

  3. Start the PFM - Manager services.

    For details about how to start the services, see 1.2.1 Starting services on monitoring managers and monitoring agents.