Hitachi

JP1 Version 12 JP1/Performance Management User's Guide


6.6.4 Starting monitoring with an alarm

You can temporarily stop, and then start monitoring with an alarm without unbinding the alarm from the monitoring agent.

  1. Log on to PFM - Web Console from the Web browser of the monitoring console.

    You must log on as a user with administrator user permissions.

  2. In the navigation frame of the main window, select the Alarms tab.

  3. In the navigation frame of the Alarms window, select the alarm tables to start monitoring from the folder of the monitoring agent.

    The selected alarm table is marked with a checkmark.

  4. In the method frame, select Activate.

  5. Change the Activate setting in the Activate window.

    Check Activate for the alarm for which monitoring is to start.

  6. Click the OK button.

    The monitoring with the alarm starts.