Hitachi

JP1 Version 12 JP1/Performance Management User's Guide


6.4.11 Importing alarm tables

  1. Log on to PFM - Web Console from the Web browser of the monitoring console.

  2. In the navigation frame of the main window, select the Alarms tab.

  3. In the method frame of the Alarms window, select the Import method.

  4. In the Import window, click the Browse button beside Import file name.

    The operating system displays a dialog box in which you can choose a file. Select the definition file of the alarm to be imported. The root, folders, and alarm tables described in the definition file to be selected here are imported. When you select a file, a confirmation message box appears.

  5. If you want to replace the definition file of the alarm table, click the OK button in the message box.

    The alarm tables are imported.

Note:
  • If importing an alarm table causes one of the already bound alarm tables to be overwritten, the alarm table is unbound. You must rebind the alarm table, if necessary.

  • When you import an alarm table to PFM - Manager which does not support monitoring of operating status for each instance, the alarms in alarm table are imported as alarms for which State changes for the alarm is selected.