Hitachi

JP1 Version 12 JP1/Performance Management User's Guide


5.8.1 Preparing to display combination reports

The following preparations are required before you can display a combination report:

For details on how to create reports to display in a combination report, 5.2 Overview and procedure for report creation. For details on how to register reports with a combination bookmark, see 5.6.1 Creating bookmarks.

Note

You can register a total of 10 reports and baselines in a combination bookmark.

Organization of this subsection

(1) Registering a baseline in a combination bookmark

  1. Display the View Report window for registering a baseline in a combination bookmark in the window of PFM - Web Console.

    For details on how to display the View Report window, see 5.7.1 Displaying reports.

  2. Select the Baseline in the View Report window.

  3. From the Bookmarks tree in the Baseline window, select a combination bookmark and enter the name of the baseline in Specify the baseline name.

    Specify the baseline name

    Enter a baseline name using 1 to 64 single or double-byte characters. You can enter a combination of single and double-byte characters.

  4. Click the OK button.

    The baseline is registered in the combination bookmark.

(2) Setting the display format of a combination report

To set the display format of a combination report, edit the display conditions for combination bookmarks:

  1. From the monitoring console Web browser, log on to PFM - Web Console.

  2. In the navigation frame of the main window, choose the Bookmarks tab.

  3. From the Bookmarks tree in the navigation frame of the Bookmark window, select the combination bookmark you created.

    The selected combination bookmark is marked with a checkmark.

  4. From the method frame, choose the Edit method.

    In the information frame, the Edit window appears.

  5. Edit the display conditions as needed in the Edit window in the information frame.

    You can group the reports of a combination report in the Series group settings area of the Edit window, as a series group. You can set and modify the following settings for each series group:

    • Graph type

    • Series group name

    • Maximum and minimum values of the Y-axis

    • Y-axis display position

  6. Click the OK button.

    The series group settings take effect as the display settings for the combination report.