Hitachi

JP1 Version 12 JP1/Performance Management User's Guide


5.3.7 Setting the display format (table, list, or graph) of a report

You can select the report display style from the following three formats, and you can also display data in multiple formats for a single report.

Organization of this subsection

(1) Setting components of a report

  1. Set the necessary information for the display format.

    For example, when defining a realtime report of the top ten processes whose CPU usage ratio is high in PFM - Agent for Platform (Windows), if you want to display the report of each field of Process Detail (PD) records in table format and display the CPU % (PCT_PROCESSOR_TIME) fields report in graph format, specify the following settings:

    CPU%: Select Table and Graph

    PID: Select Table

    Program: Select Table

    Display key

    Field: CPU%

    In descending order: Do not select

  2. Click the Next > button.

(2) Setting a graph type

  1. Set the graph type and the necessary information for the display format.

    For example, when defining a realtime report of the top ten processes whose CPU usage ratio is high in PFM - Agent for Platform (Windows), you could use the following conditions to display the graph of CPU % (PCT_PROCESSOR_TIME) fields report of Process Detail (PD) records:

    Conditions:

    • The CPU % (PCT_PROCESSOR_TIME) field value is set for the vertical axis.

    • The program (INSTANCE) field name is set for the horizontal axis and PID (ID_PROCESS) field value is set for the data within the parentheses.

    • The bar graph is set for the graph type.

    Set as follows:

    Graph types

    Column: Select

    Series direction

    By row: Select

    Axis labels

    X-axis: Program (PID)

    Y-axis: CPU%

    Data label

    Data label 1: Program

    Data label 2: PID

  2. Click the Next > button.

    The New Report > Drilldown windows appears. Go to 5.3.8 Associating a report with another report (drilldown report).

    Supplemental information:

    If you do not want to define a drilldown report, click the Finish button to close the report setting.