Hitachi

JP1 Version 12 JP1/Performance Management Planning and Configuration Guide


A.4 Number limits for alarms and alarm tables

Table A‒3: Maximum numbers of alarms and alarm tables

Description

Maximum

Number of alarms that can be set throughout the entire Performance Management system

20,000

Number of alarms that can be defined per alarm table

250

Number of actions that can be set per alarm

9

Number of reports that can be set per alarm

1

Number of alarm tables that can be used throughout the entire Performance Management system

10,000#1

Number of alarm tables that can be bound to one agent

50

Number of alarms that can be bound to one agent

250#2

#1

As many as 1,024 alarm tables can be created within each alarm hierarchy folder.

#2

In terms of specification, the maximum number of alarms that can be handled by Performance Management is 2,500. However, processing of PFM - Manager, PFM - Agent, or PFM - RM slows down if the number of alarms exceeds 250.