Hitachi

JP1 Version 12 JP1/Base Messages


KAVA3909-W

Log data from the termination previous to this startup might not be registered as JP1 events. (event server = event-server-name, target host = monitored-host, monitor name = monitored-name)

No JP1 events might be logged during the period from the previous termination to this startup.

(S)

Continues remote monitoring.

(O)

Make sure that:

  • Monitored messages had not been output to the monitored log since the system terminated previously until this message was output.

  • If this message is output in a cluster environment, the wait for termination might time out too early. Set a longer timeout value.

  • To investigate why this message was output, use the data collection tool to collect data about JP1/IM and JP1/Base, and then contact the system administrator.