Hitachi

JP1 Version 12 JP1/Base Messages


KAVA2101-E

Event registration failed. (function = function, code = detail-code).

An error occurred during event registration for the SNMP trap converter.

(S)

Aborts the JP1 event data that caused the error, and continues processing.

(O)

If detail-code is not 40, contact the system administrator.

If detail-code is 40 (cannot connect to the event service), make sure that:

  • The event service is running. (You can check this by using the jevstat command.)

  • The service name specified for the ports parameter as an application port in the event server settings file (conf) is set in the services file.

  • Communication is possible between the address specified for the ports parameter in the event server settings file (conf) and the addresses specified for the server and client parameters in the API settings file.

  • When JP1/Base is operating with the ANY binding method on a host that uses IPv6 addresses, the IPv6 address of the local host is set in the jp1hosts2 information.