hntr2utl2 (Windows only)
- Organization of this page
Function
The hntr2utl2 command changes the size, number, and output path of the integrated trace logs output by the Hitachi Network Objectplaza Trace Library (HNTRLib2).
At command execution, the following dialog box appears.
In this dialog box, you can set the size, number, and output path of the HNTRLib2 log files. The dialog box has the following components.
- Output (directory and prefix)
-
Enter the output directory and the file name prefix. The following output destination is specified by default:
- In Windows (x86 environment):
-
system-drive\Program Files\Hitachi\HNTRLib2\spool\hntr2*.log
- In Windows (x64 environment):
-
HNTRLib2 for 32bit (If setting an integrated trace for 32-bit processes)
system-drive\Program Files (x86)\Hitachi\HNTRLib2\spool\hntr2*.log
HNTRLib2 for 64bit (If setting an integrated trace for 64-bit processes)
system-drive\Program Files\Hitachi\HNTRLib2\spool\hntr2*.log
- Number of Files
-
Enter the number of log files (1 to 16). The default is 4. The specified number of log files are created in the output directory that you specified in Output.
- File Size (KB)
-
Specify the log file size (8 to 8,192 KB). The default is 256 KB.
- Buffer (KB)
-
Specify the buffer file size (8 to 2,048 KB). The initial setting is 64 KB.
- Interval Timer (Sec)
-
Specify the interval for monitoring the log file (1 to 300 seconds). The initial setting is 10 seconds.
- Lookout Span(Sec)
-
Specify the interval for monitoring the log file (1 to 3,600 seconds). Do not change this from the initial setting.
- Max Messages / Span
-
Specify the range (0 to 500) for the number of messages to be output by the command. Do not change this from the initial setting.
- OK button
-
Applies the entered settings and closes the dialog box.
- Cancel button
-
Closes the dialog box without applying the entered settings.
- Stop Monitor button
-
Terminates the monitoring process currently executing. You can stop the HNTRLib2 service (service name: Hitachi Network Objectplaza Trace Monitor 2) using the Stop Monitor button, but you should normally do this from the Services dialog box that opens from the Windows Control Panel.
Format
hntr2utl2
Required execution permission
Administrators
Command directory
- In Windows (x86 environment):
-
HNTRLib2 for 32bit
system-drive\Program Files\Hitachi\HNTRLib2\bin\
- In Windows (x64 environment):
-
HNTRLib2 for 32bit (If setting an integrated trace for 32-bit processes)
system-drive\Program Files (x86)\Hitachi\HNTRLib2\bin\
HNTRLib2 for 64bit (If setting an integrated trace for 64-bit processes)
system-drive\Program Files\Hitachi\HNTRLib2\bin\
Notes
-
The following shows the amount of log data that each program outputs each day. You should consider these values when specifying log file sizes. The value of each calculation formula provides the amount of log data output during normal operation. You should specify a larger size to handle errors.
- Process management
-
3.1 x number-of-starts-and-stops-per-day (kilobytes)
The above formula obtains the amount of log data for a single product. Estimate the amount of log data for each of JP1/Base, JP1/IM, and JP1/AJS.
- Authentication server
-
0.2 x number-of-logins-from-JP1/AJS - View + 0.2 x number-of-command-executions (kilobytes)
- JP1/IM
-
(0.16 + automated-action-command-length) x number-of-times-automated-action-runs-per-day + 0.4 x number-of-times-automated-action-is-changed-from-JP1/IM - View + 0.16 x number-of-logins-from-JP1/IM - View-to-JP1/IM - Manager + (0.16 + command-length-on-command-execution-screen) x number-of-command-executions-per-day (kilobytes)
- JP1/AJS
-
number-of-times-startup-conditions-are-satisfied x 0.2 (kilobytes)
-
If you modified the settings for the Hitachi Network Objectplaza Trace Library (HNTRLib2), you must restart it. From the Control Panel, open the Services dialog box, and then restart the HNTRLib2 service (service name: Hitachi Network Objectplaza Trace Monitor 2).
-
If you modified the buffer file size, restart all the services that output log data to the integrated trace log. The setting will not take effect if you do not restart them.