Hitachi

JP1 Version 12 JP1/Integrated Management 2 - Manager Command, Definition File and API Reference


8.10.1 IM Monitoring system-monitoring object

Table 8‒30: Overview of the system-monitoring object

Item

Description

Monitoring node type

IM Monitoring

Purpose

Monitoring of JP1/IM - Manager itself for failures

Basic information

Host name

Host name of the manager where JP1/IM - Manager is installed

Example: host01

Table 8‒31: Status change conditions

Status change condition

Common condition# and individual condition

Condition name

Status

Condition

Values to be compared

System warning event (IM)

Warning

System warning event (IM)#

Event ID (B.ID)

000020E6, 000020E7, 00003F91

Event-issuing server name (B.SOURCESERVER)

Host name in the basic information

System error event (IM)

Error

System error event (IM)#

Event ID (B.ID)

00002010, 00002011, 00002012, 00002020, 00002021, 000020A0, 000020E2, 000020E5, 000020E8, 00003F90

Event-issuing server name (B.SOURCESERVER)

Host name in the basic information

#: This is a common condition (condition commonly used in monitoring objects).