JP1 Version 12 JP1/Integrated Management 2 - Manager Messages


KAJY32101-E

The operation-name operation could not be performed on the Integrated Monitoring Database because an error occurred while communicating with the Event Console Server.

The effects of the operation indicated in the message could not be applied to the integrated monitoring database because an error occurred during communication with the Event Console Service.

The possible causes are as follows:

S:

Suspends processing.

O:

Take corrective action according to the cause of the error.

  • Make sure that the manager is running.

  • Make sure that the Event Service is running.

  • If you are using an integrated monitoring database, execute the jimdbstatus command to check the status of the IM database service of the manager host. Make sure that the IM database service is operating, and then retry the operation.

  • If you are using the communication encryption function, check its settings for errors.