KAJY32010-W

The acquisition of events from the integrated monitoring database was interrupted because the set event search limit was reached. (serial number in the event database : serial-number-in-event-database)

The acquisition of events was interrupted because the specified event search limit was reached. The possible causes are as follows:

S:

Suspends acquisition of the events.

O:

Check if the setting changes to the business group have taken effect in the Intelligent Integrated Management Base. If not, execute the jddcreatetree command and then execute the jddupdatetree command.

If an event receiver filter is specified, take the following corrective actions:

  • If the message is output to the display:

    If you want to resume event acquisition from the point where it was interrupted, click the Previous button or the Next button in the Events area.

    In addition, see 5.4.2 Notes on using event receiver filters in the manual JP1/Integrated Management 2 - Manager Administration Guide to consider changing the event search limit if necessary.

  • If the message is output by the REST API:

    If you want to resume event acquisition from the point where it was interrupted, specify endSid in the response body for the since parameter, and then try again.