The specified unit name is invalid. (plugin : plug-in-name, function : function-name, details : detailed-information)

The unit name specified in the IM management node link definition file is invalid.

S:

The plug-in does not acquire information about the target unit. Processing continues.

O:

The probable causes are as follows.

  • There is an error in the specification of precedingJob

    It is not the same name as the root jobnet specified in from

    It is not a unit under the root jobnet specified in from

  • There is an error in the specification of succeedingJob

    It is not the same name as the root jobnet specified in to

    It is not a unit under the root jobnet specified in to

  • The character string specified for from, to, precedingJob, and succeedingJob is too long

Please specify correctly in the IM management node link definition file. If the information must take effect in the Intelligent Integrated Management server, execute the jddupdatetree command to apply the definitions to the Intelligent Integrated Management server, and then retry the operation. Take the corrective action, and then try again.

If the cause is unknown, use the data collection tool to collect data, and then contact a system administrator.