Hitachi

JP1 Version 12 JP1/Integrated Management 2 - Manager Messages


KNAN26351-E

All trapping of remote log files on monitored host "monitored-host-name" will now stop. (cause = cause)

Remote-monitoring log file traps will now stop due to one of the following causes:

- Collection of remote host information failed.

- The OS of the monitored host changed.

S:

Stops all remote-monitoring log file traps on the monitored host.

O:

Perform the corrective action that corresponds to whichever of the following causes of error is applicable.

If the problem cannot be resolved, use the data collection tool to collect data, and then contact a system administrator.

  • If Collection of remote host information failed is displayed for cause, re-execute the collection of host information from the remote host, wait for the processing to terminate normally, and then restart the remote-monitoring log file traps that were stopped.

  • If The OS of the monitored host changed is displayed for cause, make sure that the monitored host is correct.

If the monitored host is correct, make sure that the remote monitoring profile settings are appropriate for the new OS, and then restart the remote-monitoring log file traps that were stopped. Note that the next time remote monitoring starts, the remote-monitoring log file traps cannot be carried over from when they were last stopped.

If the monitored host is incorrect, revise the system configuration.