Hitachi

JP1 Version 12 JP1/Integrated Management 2 - Manager Messages


KNAN21174-E

Application of changes failed because an error occurred when moving the configuration file (file-name) for profile-type.

Detail Information: detailed-information

Edited contents might be stored in host (host-name) because rollback of configuration file is also failed.

Changes could not be applied because an attempt to move the configuration file failed.

Another possibility is that an attempt to roll back the configuration file failed because the host version is 08-50 or earlier.

S:

Suspends processing.

O:

If the following detailed information is displayed, take the indicated corrective action.

  • There is no access permission.

    Check the setting of the host access control definition file (jbsdfts_srv.conf) in JP1/Base on the agent host.

  • Another session has exclusive rights.

    In the Login User List window, determine whether the user has acquired exclusive permission.

    If it is not problematic to do so, select the check box next to the user that has acquired exclusive permission, and then click the Release Exclusive Editing button to release exclusive permission.

  • The directory does not exist.

    Make sure that the directory exists and that it is accessible.

  • A required service or process is not running.

    Make sure that the relevant service or process is running. If it is not running, take the following actions, and then retry the operation.

    • Start the service or process.

    • In the Display/Edit Profiles window, click Operation, and then Rebuild Profile Tree.

  • A communication error occurred.

    Determine whether the relevant host exists.

    If the host exists, make sure that the network is available.

  • The processing is busy. Please try again.

    Wait awhile, and then retry the operation.

  • A service or process failed to reload.

    Make sure that the relevant service or process is running and that the configuration file is correctly formatted.

    If it is not running, take the following actions, and then retry the operation.

    • Start the service or process.

    • In the Display/Edit Profiles window, click Operation, and then Rebuild Profile Tree.

If detailed information other than the above is output, use the data collection tool to collect data, and then contact a system administrator.