KAVB4711-W

The event base service cannot use common exclusion condition groups (extended) because an event acquisition filter (for compatibility) is set.

Event Base Service cannot use common exclusion-condition groups in extended mode because an event acquisition filter (for compatibility) is set.

S:

Continues processing using the event acquisition filter (for compatibility).

O:

To extend common exclusion-condition groups, you need to change the location of the event acquisition filter from Event Console Service to Event Base Service.

Use the jcochafmode command to change the location of the filter, and then restart JP1/IM - Manager.

Note that you cannot undo the jcochafmode command that changes the location of the event acquisition filter.

If you do not want to extend the common exclusion-condition groups, execute the jcochcefmode command in JP1/IM - Manager as shown below to set the operation mode for the common exclusion-condition groups to basic mode.

jcochcefmode -m default [-h logical-host-name]