Organization of this subsection

(1) Setup for using system-monitoring objects for monitoring

To use a system-monitoring object of JP1/PFM, you must set JP1/PFM to issue JP1 events as described below. JP1/PFM supports automatic monitoring tree generation. To enable the linkage for automatic generation, set up the linkage program.

For details about the linkage setup, also see the following manual:

(a) For the JP1/PFM - Manager host

To perform setup at the manager where JP1/PFM - Manager is installed:

  1. Enable JP1 event issuance by JP1/PFM.

    Set JP1/PFM to issue JP1 events by command execution actions in alarm definitions.

  • If you remove an attribute from or set a non-default attribute value in the arguments of the jpcimevt command that issues JP1 events, the status of system-monitoring objects can no longer be monitored.

  • If you clear the Convert the alarm level to the severity level check box, the status of system-monitoring objects can no longer be monitored.

(2) Setup for generating a monitoring tree automatically

JP1/PFM supports automatic monitoring tree generation. To enable the linkage for automatic generation, set up the linkage program.

For details about the linkage setup, also see the following manual:

(a) For the JP1/PFM - Manager host

To perform setup at the manager where JP1/PFM - Manager is installed:

  1. Setting up the linkage program for JP1/PFM

    Execute the following command to enable collection of definition information from JP1/PFM when the monitoring tree is generated automatically:

    jpcimsetup -i (when enabling the linkage for automatic generation)

    If the above setup is not completed, a JP1/PFM monitoring object is not created when an attempt is made to generate a monitoring tree automatically.

    To release the linkage, execute the following command:

    jpcimsetup -u (when releasing the linkage for automatic generation)